PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 7, 2026Nutrition & Metabolism0 citationsOpen Access

Higher salivary nitrite is associated with improved glycemic control and insulin sensitivity in patients with type 2 diabetes

View Full Paper
ZBZahra BahadoranResearch Institute for Endocrine SciencesRNReza NorouziradDezful University of Medical SciencesSJSajad JeddiResearch Institute for Endocrine Sciences

Key Points

  • This research investigates the relationship between salivary nitrite and metabolic parameters in type 2 diabetes patients.
  • Conducted a cross-sectional study with 64 adults with type 2 diabetes (T2DM).
  • Measured salivary NO2 concentrations, glycemic parameters, and other metabolic health indicators.
  • Compared high- and low-salivary nitrite groups based on specific thresholds.
  • Participants with higher salivary nitrite showed lower HbA1c levels (6.2% vs. 6.9%).
  • Higher insulin sensitivity indicated by lower fasting insulin and HOMA-IR in high salivary nitrite group.
  • Greater serum nitric oxide metabolites in high salivary nitrite group.

Abstract

Salivary nitrite (SNO2), a marker of oral nitrate-reducing capacity and nitric oxide (NO) bioavailability, often impaired in type 2 diabetes (T2DM). This study aimed to investigate the associations between SNO2 concentration, and metabolic, vascular, and renal parameters in patients with T2DM. Sixty-four adults with T2DM (53.9 ± 7.2 years, 45.3% men, diabetes duration 8.3 ± 6.2 years) participated in this cross-sectional study. Salivary NO2 concentrations, glycemic parameters, blood pressure (BP) indices, renal function, lipid profiles, liver function, and systemic NO metabolites were measured. Participants with high- and low-SNO2 (< and ≥ 69.3 µmol/L) were compared for cardiometabolic parameters. Compared with the low-SNO2 group, participants with higher SNO2 had lower HbA1c (6.2% vs. 6.9%, P = 0.040), fasting insulin (6.1 vs. 8.2 µU/mL, P = 0.007), HOMA-IR (2.1 vs. 3.3, P = 0.003), and C-peptide (1.3 vs. 1.7 ng/mL, P = 0.023), with higher QUICKI (0.34 vs. 0.32, P = 0.003). Fasting serum glucose was marginally lower (142 vs. 167 mg/dL, P = 0.069) in the high- compared to the low-SNO2 group. Median serum nitric oxide metabolites (NOx) concentrations were higher in the high-SNO2 group (51.1 vs. 29.1 µmol/L, P = 0.015). Salivary nitrate (NO3) (694 vs. 463 µmol/L, P = 0.035) and NO2 (153 vs. 20.6, P = 0.001) were also higher in the high- compared to low-SNO2 group. No significant difference was observed in BP measures, lipid profile, and liver and renal function test across groups. High-SNO2 levels were associated with greater glycemic control, insulin sensitivity, and NO bioavailability in patients with T2DM.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bahadoran et al. (2026) studied this question.

synapsesocial.com/papers/69fbe382164b5133a91a2ce1https://doi.org/10.1186/s12986-026-01104-5
Ask AI
Helpful
Bookmark
Share
View Full Paper