PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 7, 2026Current Medical Imaging Formerly Current Medical Imaging Reviews0 citations

Automatic Recognition Algorithm for Renal Tumors and Cysts in CT Imagesusing Mamba and YOLO11

View Full Paper
JJJiang JialiZCZhaoxue Chen

Key Points

  • The research aims to improve detection methods for renal tumors and cysts in CT images using YOLO11.
  • Developed YOLO11-based detection model with Mamba-inspired architecture.
  • Introduced gated state-space modeling to enhance spatial and channel information.
  • Implemented a Dynamic Upsampling module for improved multi-scale feature fusion.
  • Integrated a Multi-Dimensional Local Channel Attention mechanism before detection head.
  • Achieved precision of 0.837 and recall of 0.636 with improved metrics over YOLO11 model.
  • Demonstrated mAP@0.5 of 0.732 and mAP@0.5:0.95 of 0.505, indicating enhanced detection performance.

Abstract

INTRODUCTION: Renal tumors pose a serious threat to patient health and survival, highlighting the importance of early detection and accurate diagnosis. In clinical practice, differentiating renal tumors from cysts in CT images remains challenging due to similar imaging characteristics and complex anatomical structures. The aim of this study is to develop an improved detection method for renal tumors and cysts based on an enhanced YOLO11 framework. METHODS: An improved YOLO11-based detection model incorporating a Mamba-inspired architecture is proposed. A gated state-space modeling module is introduced into the backbone network to enhance the modeling capability of spatial and channel information and effectively focus on key regional features. A Dynamic Upsampling module (DySample) is then adopted in the neck network to improve multi-scale feature fusion. In addition, a Multi-Dimensional Local Channel Attention (MLCA) mechanism is integrated before the detection head to jointly refine spatial and channel features, thereby enhancing the localization capability for lesion areas. RESULTS: Experimental results demonstrate that the proposed method achieves a precision of 0.837, a recall of 0.636, mAP@0.5 of 0.732, and mAP@0.5:0.95 of 0.505. Compared with the YOLO11 model, these metrics are improved by 3.1%, 0.1%, 2.1%, and 2.5%, respectively, indicating an overall enhancement in detection performance. DISCUSSION: YOLO11-Mamba has achieved improvements in detection accuracy and localization performance, but there are still some potential limitations. Among these, the introduction of state space models and attention mechanisms has increased the model's parameter count and computational complexity to some extent, which may pose challenges for clinical deployment, pointing the way for future research. CONCLUSION: The proposed method demonstrates effective performance in the detection of renal tumors and cysts from CT images. The results show fewer missed detections and improved lesion localization accuracy, suggesting the proposed model is a promising tool for renal lesion detection and clinical imaging.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jiali et al. (2026) studied this question.

synapsesocial.com/papers/69fbefef164b5133a91a4046https://doi.org/10.2174/0115734056450311260425112727
Ask AI
Helpful
Bookmark
Share
View Full Paper