Structural Controls on Groundwater Salinization and Borehole Failure in the Upper Blue Nile Basin, Ethiopia

View Full Paper
EGEndalkachew Abebaw GizawGBGetnet Taye BawokeMAMelkamu Meseret Alemu

Key Points

  • This research aims to determine whether fault systems influence groundwater salinization and borehole failures in the Upper Blue Nile Basin.
  • Integrated hydrochemistry and stable isotopes (δ 18 O, δ 2 H) analyses
  • Utilized Hierarchical Cluster Analysis (HCA) and Principal Component Analysis (PCA)
  • Focused on the Fetam-Yisir watershed in the Upper Blue Nile Basin
  • Identified two distinct groundwater systems: low-salinity (<1,800 mg/L) and high-salinity (>9,000 mg/L) confined to the fault zone
  • Marked isotopic depletion in fault-zone waters indicates the ascent of deep, evolved groundwater
  • Established a structural model that assists in predictive well-siting strategies

Abstract

Groundwater salinization causes recurrent borehole failures in the Fetam-Yisir watershed, Upper Blue Nile Basin, yet its origin remains uncertain. This study investigates whether a major west-east fault system controls this salinity, challenging conventional regional recharge models. We integrated hydrochemistry, stable isotopes (δ 18 O, δ 2 H), and multivariate statistics, specifically Hierarchical Cluster Analysis (HCA) and Principal Component Analysis (PCA), to distinguish groundwater populations and governing processes. Results reveal two distinct systems. Regional meteoric groundwater (Mg-Na-HCO₃ to Na-Mg-HCO₃; TDS 9,000 mg/L) is strictly confined to the Bure-Baguna fault corridor. These fault-zone waters exhibit marked isotopic depletion (δ 18 O: -5.6‰ to -2.6‰) and stoichiometric cation exchange (slope ≈ -1), indicating the fault-driven ascent of deep, highly evolved groundwater from underlying carbonates. Consequently, the fault acts dually as a vertical conduit for deep fluids and a lateral barrier preventing widespread mixing. This structural model enables predictive well-siting strategies and provides a transferable framework for diagnosing fault-controlled salinization in tectonically complex aquifers. • Fault-controlled salinization explains recurrent borehole failure in the Upper Blue Nile Basin. • High-salinity Na-HCO₃ groundwater (>9,000 mg/L) is confined to the west-east Bure-Baguna fault zone. • Stable isotopes identify deep, evolved paleo-meteoric groundwater. • Stoichiometric cation exchange signatures (slope ≈ -1) strongly indicate carbonate-derived salinity modified during fault ascent. • Structural mapping and spatial hydrochemical gradients support precautionary, risk-based setbacks for well siting.