January 11, 2024European Journal of Cardio-Thoracic Surgery14 citationsOpen Access

Comparison of 4 mortality scores for surgical repair of type A aortic dissection: a multicentre external validation

View Full Paper
FPFrancesco PollariPNPaolo NardiEMElisa Mikus

Key Points

Key points are not available for this paper at this time.

Abstract

OBJECTIVES: In the last decades, 4 different scores for the prediction of mortality following surgery for type A acute aortic dissection (TAAD) were proposed. We aimed to validate these scores in a large external multicentre cohort. METHODS: We retrospectively analysed patients who underwent surgery for TAAD between 2000 and 2020. Patients were enrolled from 10 centres from 2 European countries. Outcomes were the early (30-day and/or in-hospital) and 1-year mortality. Discrimination, calibration and observed/expected (O/E) ratio were evaluated. RESULTS: A total of 1895 patients (31.7% females, mean age 63.72 ± 12.8 years) were included in the study. Thirty-day mortality and in-hospital mortality were 21.7% (n = 412) and 22.5% (n = 427) respectively. The German Registry of Acute Aortic Dissection Type A (GERAADA) score shows to have the best discrimination area under the curve (AUC) 0.671 and 0.672 in predicting as well the early and the 1-year mortality, followed by the International Registry of Acute Aortic Dissection (IRAD) model 1 (AUC 0.658 and 0.672), the Centofanti (AUC 0.645 and 0.66) and the UK aortic score (AUC 0.549 and 0.563). According to Hosmer-Lemeshow and Brier tests, the IRAD model I and GERAADA, respectively, were well calibrated for the early mortality, while the GERAADA and Centofanti for the 1-year mortality. The O/E analysis showed a marked underestimation for patients labelled as low-risk for UK aortic score and IRAD model I for both outcomes. CONCLUSIONS: The GERAADA score showed the best performance in comparison with other scores. However, none of them achieved together a fair discrimination and a good calibration for predicting either the early or the 1-year mortality.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Pollari et al. (2024) studied this question.

synapsesocial.com/papers/69ff6e816018b8d0892d7fc0https://doi.org/10.1093/ejcts/ezae005
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 12014 ESC Guidelines on the diagnosis and treatment of aortic diseases2014 · 4,502 citations
  2. 2Prediction of mortality rate in acute type A dissection: the German Registry for Acute Type A Aortic Dissection score2020 · 160 citations
  3. 3Validation of the German Registry for Acute Aortic Dissection Type A Score in predicting 30-day mortality after type A aortic dissection surgery2023 · 31 citations