PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 7, 2022Journal of Prosthodontics63 citations

Digital vs Conventional Full‐Arch Implant Impressions: A Retrospective Analysis of 36 Edentulous Jaws

View Full Paper
PPPanos PapaspyridakosASAndré De SouzaMFMatthew Finkelman

Key Points

Key points are not available for this paper at this time.

Abstract

PURPOSE: There is a paucity of comparative clinical studies assessing the accuracy of full-arch digital scans versus conventional implant impressions. The aim of this retrospective study was to compare the three-dimensional (3D) deviations between full-arch digital scans and conventional implant impressions for edentulous maxillae and mandibles. MATERIALS AND METHODS: Twenty-seven patients (36 edentulous jaws) were treated with one-piece, screw-retained implant-supported fixed complete dental prostheses (IFCDPs). Twenty-one jaws were maxillary, and 15 were mandibular. Full-arch conventional impressions and intraoral digital scans with scan bodies and an intraoral scanner had been taken during the impression phase. Following verification of the conventional stone casts, the casts were digitized. The generated standard tessellation language (STL) files from both impression techniques were merged and analyzed with reverse engineering software. The primary aim was to evaluate the accuracy between conventional and digital full-arch scans, while the effect of the edentulous jaw in 3D accuracy was the secondary aim. RESULTS: The cumulative 3D (mean ± SD) deviations between virtual casts from intraoral full-arch digital scans and digitized stone casts generated from conventional implant impressions were found to be 88 ±24 μm. In the maxillary group, the mean ± SD 3D deviation was 85 ±25 μm, compared to 92 ±23 μm for the mandibular group (p = 0.444). CONCLUSION: The 3D implant deviations found between the full-arch digital and conventional impressions lie within the clinically acceptable threshold. No statistically significant difference was identified between maxillary and mandibular jaws in terms of 3D deviations.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Papaspyridakos et al. (2022) studied this question.

synapsesocial.com/papers/69ffd69f831589f3542daaf5https://doi.org/10.1111/jopr.13536
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Complete Digital Workflow for Mandibular Full‐Arch Implant Rehabilitation in 3 Appointments2021 · 74 citations
  2. 2Comparison of Three-Dimensional Accuracy of Digital and Conventional Implant Impressions: Effect of Interimplant Distance in an Edentulous Arch2018 · 112 citations
  3. 3Rehabilitation of edentulous jaws with zirconia complete-arch fixed implant-supported prostheses: An up to 4-year retrospective clinical study2018 · 66 citations
  4. 4Maxillary complete-arch implant-supported restoration: A digital scanning and maxillomandibular relationship workflow2020 · 37 citations
  5. 5Introduction to the Practice of Statistics2001 · 415 citations