May 10, 2026Pediatric Pulmonology0 citations

Spirometry Assessments in Children With Sickle Cell Disease in Ghana

View Full Paper
BBBaah Agyeiwah BirgitNENtim Amankwa EmmanuelOEOsei Eugenia

Key Points

  • This study aimed to assess spirometry patterns in Ghanaian children with sickle cell disease and identify contributing factors to low lung function.
  • Conducted a case-control study involving children aged 6-16 years with and without sickle cell disease.
  • Collected demographic, socio-economic, and clinical information alongside spirometry assessments.
  • Analyses included logistic and linear regression to evaluate lung function patterns.
  • Children with sickle cell disease had lower mean z-scores for forced vital capacity (FVC) compared to controls (-0.8 vs -0.3, p < 0.001).
  • Abnormal lung function was found more frequently in cases (42%) than controls (17.4%), with significant differences in restrictive and obstructive patterns.
  • Higher BMI z-scores were linked to lower odds of restrictive lung function pattern (OR 0.31, 95% CI 0.16, 0.58, p < 0.001).

Abstract

BACKGROUND: Pulmonary disease in children with SCD is common and heterogeneous and includes pulmonary function impairment. This study aimed to investigate spirometry patterns in Ghanaian children with SCD and factors that contribute to low lung function. METHODS: A case-control study involving children aged 6-16 years with and without SCD was carried out at the Komfo Anokye Teaching Hospital. Demographic, socio-economic, and clinical information were collected. Spirometry was performed for both cases and controls at enrolment and interpreted based on the GLI-Black reference equation. Logistic and linear regression analyses were performed. RESULTS: , cases vs controls, -1.0 (SD1.2) vs -0.4 (SD 1.2) z-score, (p < 0.001), mean z-scores for forced vital capacity (FVC z-scores), cases versus controls, -0.8 (SD1.2) z score vs -0.3 (SD 1.3) z-score, (p < 0.001). Abnormal lung function was significantly more common in cases than controls, 42% (n = 48) and 17.4% (n = 20) respectively. The lung function abnormalities noted were as follows: restrictive pattern, cases versus controls 24.3% (n = 28) vs 12.2% (n = 14) (p < 0.001), obstructive pattern 14.8% (n = 17) versus 5.2% (n = 6) (p < 0.001), mixed pattern [2.6% (n = 3) versus 0 (p < 0.001). Being female and having higher BMI z-scores were associated with significantly lower odds of having a restrictive lung function pattern compared to normal lung function, OR 0.31 (95% CI 0.16, 0.58) (p < 0.001). CONCLUSION: This study has demonstrated a predominance of low anthropometric measurements and restrictive abnormality on spirometry in children with SCD in Ghana. Females and those with higher BMI z-scores had significantly lower odds of having a restrictive lung function pattern compared to normal lung function.