November 3, 2016Translational Vision Science & Technology107 citationsOpen Access

A Comparison of Perimetric Results from a Tablet Perimeter and Humphrey Field Analyzer in Glaucoma Patients

YKYu KongMHMingguang HeJCJonathan G. Crowston

Key Points

Key points are not available for this paper at this time.

Abstract

PURPOSE: To determine the correlation between the perimetric outcomes from perimetry software Melbourne Rapid Fields (MRF) run on an Apple iPad tablet and those from the Humphrey Field Analyzer (HFA). METHODS: The MRF software was designed with features including variable fixation and fast thresholding using Bayes logic. Here, we report a cross-sectional study on 90 eyes from 90 participants: 12 had normal optic nerves and 78 had glaucoma with various degrees of visual field loss (41 mild and 37 moderate-severe). Exclusion criteria were patients with worse than 20/40 vision or recent intraocular surgery. The visual field outcomes of MRF were compared against those returned from the HFA 24-2 SITA standard. Participants were tested twice on the MRF to establish test-retest repeatability. RESULTS: < 0.001). MRF showed a high level of concordance in its outcomes with HFA (intraclass coefficient ICC = 0.93 for mean defect MD and 0.86 for pattern deviation PD) although the MRF tended to give a less negative MD (1.4 dB bias) compared with the HFA. MRF also showed levels of test-retest reliability comparable to HFA (ICC = 0.93 for MD and 0.89 for PD, 95% limits of agreement -4.5 to 4.3 dB). CONCLUSION: The perimetry results from the MRF have a strong correlation to the HFA outcomes. MRF also has test-retest reliability comparable to HFA. TRANSLATIONAL RELEVANCE: Portable tablet perimetry may allow accurate assessment of visual field when standard perimetry machines are unavailable or unsuitable.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kong et al. (2016) studied this question.

synapsesocial.com/papers/6a01135bef8139f8ff77ba41https://doi.org/10.1167/tvst.5.6.2
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Validation of a Tablet as a Tangent Perimeter2016 · 84 citations
  2. 2A comparison of perimetric results with the Medmont and Humphrey perimeters2003 · 36 citations
  3. 3Efficient and unbiased modifications of the QUEST threshold method: Theory, simulations, experimental evaluation and practical implementation1994 · 454 citations
  4. 4Practical recommendations for measuring rates of visual field change in glaucoma2008 · 534 citations
  5. 5Repeatability of Automated Perimetry: A Comparison between Standard Automated Perimetry with Stimulus Size III and V, Matrix, and Motion Perimetry2009 · 151 citations