PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 1, 2014Applied Physics Letters88 citations

Application of proton boron fusion reaction to radiation therapy: A Monte Carlo simulation study

View Full Paper
DYDo‐Kun YoonJJJoo‐Young JungTSTae Suk Suh

Key Points

Key points are not available for this paper at this time.

Abstract

Three alpha particles are emitted from the point of reaction between a proton and boron. The alpha particles are effective in inducing the death of a tumor cell. After boron is accumulated in the tumor region, the emitted from outside the body proton can react with the boron in the tumor region. An increase of the proton's maximum dose level is caused by the boron and only the tumor cell is damaged more critically. In addition, a prompt gamma ray is emitted from the proton boron reaction point. Here, we show that the effectiveness of the proton boron fusion therapy was verified using Monte Carlo simulations. We found that a dramatic increase by more than half of the proton's maximum dose level was induced by the boron in the tumor region. This increase occurred only when the proton's maximum dose point was located within the boron uptake region. In addition, the 719 keV prompt gamma ray peak produced by the proton boron fusion reaction was positively detected. This therapy method features the advantages such as the application of Bragg-peak to the therapy, the accurate targeting of tumor, improved therapy effects, and the monitoring of the therapy region during treatment.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Yoon et al. (2014) studied this question.

synapsesocial.com/papers/6a032f63c8c4199b329e3e13https://doi.org/10.1063/1.4903345
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Tomographic image of prompt gamma ray from boron neutron capture therapy: A Monte Carlo simulation study2014 · 23 citations
  2. 2Calculation of water equivalent ratio of several dosimetric materials in proton therapy using FLUKA code and SRIM program2014 · 18 citations
  3. 3Interaction position resolution simulations and in-beam measurements of the AGATA HPGe detectors2011 · 51 citations
  4. 4Multifield Optimization Intensity Modulated Proton Therapy for Head and Neck Tumors: A Translation to Practice2014 · 153 citations
  5. 5Estimation of proton distribution by means of three-dimensional reconstruction of prompt gamma rays2010 · 16 citations