July 8, 2005The Journal of Physiology51 citationsOpen Access

Differences in left ventricular long‐axis function from mice to humans follow allometric scaling to ventricular size

View Full Paper
ZPZoran PopovićJSJing Ping SunHYHirotsugu Yamada

Structured PICO

P
Population
10 mice, 15 rats, 6 rabbits, 8 mongrel dogs and 38 human volunteers
I
Intervention
Doppler tissue echocardiography
O
Outcome
Allometric scaling (power-law equation Y=kMbeta) of mitral annulus peak velocity, displacement, and LV ejection time to LV end-diastolic volume and masssurrogate

Abstract

While the heart size maintains a constant proportion to body size, heart function parameters, such as heart rate and cardiac output, show a more complex scaling pattern. How these phenomena affect the long-axis left ventricular (LV) function is unknown. We studied 10 mice, 15 rats, 6 rabbits, 8 mongrel dogs and 38 human volunteers. Doppler tissue echocardiography data were postprocessed to reconstruct mitral annulus (MA) peak systolic velocity and displacement. The relationship between MA peak velocity, MA displacement and LV ejection time, and LV end-diastolic volume (and mass) were fit to an allometric (power-law) equation Y=kMbeta. LV mass varied from 0.062 to 255 g, while end-diastolic volume varied from 0.014 to 205 ml. beta values of the relation between LV ejection time and LV end-diastolic volume and mass were 0.247+/-0.017 and 0.267+/-0.018, respectively. beta values of the relationship between MA displacement and LV end-diastolic volume and mass were 0.358+/-0.047 and 0.390+/-0.051 (P<0.023 versus beta of LV ejection time). beta values of the relationship between MA peak systolic velocity and LV end-diastolic volume and mass were 0.096+/-0.012 and 0.100+/-0.013, respectively (P<0.0001 versus 0). Finally, beta values of the relationship between the long-to-short axis displacement ratio and LV end-diastolic volume and mass were 0.077+/-0.017 and 0.086+/-0.019 (P<0.0001 versus 0). We conclude that MA velocity, displacement, and long-to-short axis displacement ratio scale allometrically to heart size. This reduces the relative long-axis contribution to heart function in small mammals.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Popović et al. (2005) studied this question.

synapsesocial.com/papers/6a03c070d2c35e4200e96c85https://doi.org/10.1113/jphysiol.2005.090779
Ask AI
Helpful
Bookmark
Share
View Full Paper