PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 1, 1995Physical review. B, Condensed matter223 citations

X-ray-absorption fine-structure standards: A comparison of experiment and theory

View Full Paper
GLG. G. LiFBF. BridgesCBCorwin H. Booth

Key Points

Key points are not available for this paper at this time.

Abstract

The reliability of the structural parameters obtained from x-ray-absorption fine-structure (XAFS) spectra strongly depends on the quality of the standards used in the data analyses. We have compared about 30 isolated pair standards, extracted from experimental data, with those generated by the feff5 code. The absorbing atoms range from Ni (Z=28) to Pb (Z=82) and the backscattering atoms from O (Z=8) to Au (Z=79). In general, good agreement is achieved, with typical errors of 0. 005 for nearest-neighbor distances R. Significant differences are sometimes found in the backscattering amplitude F (k, R) at low values of the photoelectron wave vector k (7 A^-1), especially for heavy backscattering atoms such as Au and Pt. We demonstrate that when there are significant differences between experimental and theoretical functions, F (k, R), an experimental standard, shifted from one atom pair to another, provides a better fit to the data than obtained using the theoretical standard and reduces the errors in amplitude and position, often by a factor of 2--3. The effective amplitude reduction factor S₎, ₄₅₅^2 and the E₎ shift for the calculated XAFS standards are also given; the former can vary by 20% across the Periodic Table. Estimated experimental errors for the amplitudes are 10%, and 5--6 % in many cases. Some important fundamental issues, such as background removal, the influence of the energy resolution on XAFS, and correlations in the fitting parameters, are also addressed.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Li et al. (1995) studied this question.

synapsesocial.com/papers/6a070ed1d9167a9c2a584342https://doi.org/10.1103/physrevb.52.6332
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1X-ray-absorption fine structure in embedded atoms1994 · 159 citations
  2. 2Monochromator-induced glitches in EXAFS data II. Test of the model for a pinhole sample1994 · 12 citations
  3. 3American Institute of Physics Handbook1964 · 3,004 citations
  4. 4Improved ab initio calculations of amplitude and phase functions for extended x-ray absorption fine structure spectroscopy1988 · 714 citations
  5. 5Photoelectron and Auger Spectroscopy1975 · 885 citations