PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 16, 2026Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment0 citationsOpen Access

In vivo imaging demonstration using a two-dimensional SiPM-based photon-counting CT system: Preliminary results

View Full Paper
MOMinori OshimaMAM. ArimotoFLF. Lucyana

Key Points

  • This research aims to develop and evaluate a two-dimensional photon-counting computed tomography system for enhanced dynamic imaging capabilities.
  • Developed a 1024-channel two-dimensional PC-CT system using silicon photomultipliers and YGAG scintillators.
  • Conducted in vivo imaging experiments with a gadolinium-based contrast agent in a mouse model.
  • Measured energy resolution and maximum count-rate tolerance for system evaluation.
  • Average energy resolution of 41.2 ± 1.6% at 59.5 keV over 1024 channels.
  • Maximum count-rate tolerance of 6.3 MHz, comparable to prior 1D system.
  • Imaging speed increased by approximately tenfold compared to the 1D system.

Abstract

Photon-counting computed tomography (PC-CT) is a next-generation imaging technology that enables material discrimination and quantitative evaluation through energy-resolved photon detection. In our previous study, we developed a one-dimensional (1D) PC-CT system consisting of silicon photomultipliers (SiPMs; multipixel photon counters, MPPCs) coupled with yttrium-gadolinium-aluminum-gallium garnet (YGAG) scintillators in a matched 1 × 64 pixel configuration, and successfully demonstrated material discrimination and quantitative concentration estimation. In this study, as a step toward dynamic imaging, we developed a two-dimensional (2D) PC-CT system employing a 1024-channel detector array composed of 16 × 64 pixels, in which MPPCs are coupled with YGAG scintillators. Signals from the MPPCs are read out and processed using multiple custom-developed large-scale integration (LSI) circuits. We evaluated the spectroscopic and counting performance of the system and found an average energy resolution of 41 . 2 ± 1 . 6 % (FWHM at 59.5 keV) over the 1024 channels, as well as a maximum count-rate tolerance of 6.3 MHz, both of which are comparable to those of the 1D system. To demonstrate the applicability of the system to dynamic imaging, preliminary in vivo imaging experiments were performed using a mouse administered with a gadolinium-based contrast agent. As a result, the total imaging speed was increased by approximately a factor of ten compared to that of the 1D system. Furthermore, the in vivo distribution of gadolinium was successfully visualized, indicating that the developed 2D PC-CT system is promising for future dynamic clinical imaging applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Oshima et al. (2026) studied this question.

synapsesocial.com/papers/6a0808ffa487c87a6a40b098https://doi.org/10.1016/j.nima.2026.171657
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Multi-energy in-vivo imaging of multiple contrast agents in a mouse using MPPC-based photon-counting CT2024 · 12 citations
  2. 2Development of 64-channel LSI with ultrafast analog and digital signal processing dedicated for photon-counting computed tomography with multi-pixel photon counter2022 · 20 citations
  3. 3Estimation of contrast agents using a 2-dimensional photon counting CT detector combined with MPPC and YGAG scintillator array2025 · 2 citations
  4. 464-channel photon-counting computed tomography using a new MPPC-CT system2020 · 29 citations
  5. 5Theranostic Nanomedicine2011 · 862 citations