Synapse
April 1, 1967Circulation124 citations

Factors Affecting Thromboembolism Associated with Prosthetic Heart Valves

View Full Paper
GDGeorge E. DuvoisinRBRobert O. BrandenburgDMDwight C. McGoon

Key Result

Carefully controlled anticoagulation in patients with aortic ball-valve prostheses was associated with a thromboembolism risk of less than 5% at 2 years postoperatively.

Key Points

  • This research aims to examine the factors influencing thromboembolism risk following prosthetic heart valve insertion.
  • Constructed actuarial curves to analyze thromboembolism incidence over time postoperatively.
  • Reviewed cases of patients with different types of prosthetic heart valves, including aortic and mitral valves.
  • Investigated the effects of controlled anticoagulation therapy specifically in patients with ball-valve prostheses.
  • Thromboembolism risk was 15% in the first 6 months, 8% in the next 6 months, and 20% over the next 2 years.
  • Risk of embolism was notably lower than 5% for patients receiving anticoagulation therapy two years post-aortic ball-valve replacement.
  • Fatality rate from embolism averaged 15% among the patients studied.

Study Design

Type

Observational

Structured PICO

Does anticoagulation reduce the incidence of thromboembolism in patients with prosthetic cardiac valves?

P
Population
Patients who underwent insertion of prosthetic cardiac valves (aortic, mitral, and multiple-valve replacements)
I
Intervention
Anticoagulation therapy
C
Comparator
No anticoagulation or less controlled anticoagulation
O
Outcome
Incidence of thromboembolismhard clinical

Carefully controlled anticoagulation significantly reduces the risk of thromboembolism in patients with prosthetic heart valves, particularly those with ball-valve prostheses.

Abstract

The incidence of thromboembolism after insertion of prosthetic cardiac valves is related to the type of prosthesis and in the cases reviewed here was highest for the ball-valve prosthesis. The risk of thromboembolism was studied by constructing actuarial curves showing the proportion of patients with embolism at increasing time intervals postoperatively. Such curves for the patients studied suggest that the risk of thromboembolism diminishes with time, particularly by the third postoperative year. The risk was remarkably similar for patients having aortic, mitral, and multiplevalve replacements, being 15% for the first 6 postoperative months, another 8% for the next 6 months, and another 20% for the next 2 years. Emboli lodged in cerebral, coronary, renal, and other sites in these patients in diminishing frequency. The risk of fatality averaged 15%. None of the nonfatal embolisms resulted in significant continuing disability, save for 7% of the cerebral embolisms. A beneficial effect of anticoagulation was demonstrated for patients having replacement of the aortic valve with a ball-valve prosthesis, particularly when this treatment was carefully controlled. In the latter group, the risk of thromboembolism was less than 5% 2 years postoperatively.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Duvoisin et al. (1967) conducted an observational in Prosthetic heart valves. Anticoagulation was evaluated on Thromboembolism. Carefully controlled anticoagulation in patients with aortic ball-valve prostheses was associated with a thromboembolism risk of less than 5% at 2 years postoperatively.

synapsesocial.com/papers/6a08c8c6865c3eaa9b01e9e4https://doi.org/10.1161/01.cir.35.4s1.i-70
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1INCIDENCE AND PREVENTION OF ARTERIAL THROMBOEMBOLIC COMPLICATIONS IN PATIENTS WITH PROSTHETIC HEART VALVES1981
  2. 2Thromboembolic Complications of Prosthetic Cardiac Valves1968 · 122 citations
  3. 3Role of Anticoagulants in Preventing Embolization From Prosthetic Heart Valves1967 · 51 citations
  4. 4Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses.1994 · 1,068 citations
  5. 5Thrombotic and Bleeding Complications of Prosthetic Heart Valves1987 · 293 citations