July 1, 1984IEEE Transactions on Industry Applications95 citations

Modulation of the Chopping Frequency in DC Choppers and PWM Inverters Having Current-Hysteresis Controllers

View Full Paper
WMWilliam McMurray

Key Points

Key points are not available for this paper at this time.

Abstract

In a dc chopper converter having its load current regulated by a feedback controller of the fixed hysteresis type, the chopping frequency is shown to depend on the square of the counter EMF of the load. In a pulsewidth modulated (PWM) inverter, the counter EMF is modulated at the output frequency, so the chopping frequency is modulated at twice the output frequency. For a three-phase PWM inverter feeding a three-wire load, the chopping frequency modulation is not smooth. This is explained to be a consequence of the fact that the three phase currents must sum to zero, rendering one of the three current controllers redundant.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

William McMurray (1984) studied this question.

synapsesocial.com/papers/6a08ed89873af4998be4ac4ahttps://doi.org/10.1109/tia.1984.4504485