Key Result

ECG pattern analysis using empirical mode decomposition demonstrated the feasibility of determining emotional valence from ECG morphology, achieving up to 89% accuracy in 44 subjects.

Structured PICO

P
Population
44 subjects
I
Intervention
ECG pattern analysis using empirical mode decomposition and Hilbert-Huang transform
O
Outcome
Detection of dynamically evolving emotion patterns (active arousal and passive arousal/valence)surrogate

ECG pattern analysis using empirical mode decomposition can accurately detect emotion patterns, specifically valence, with up to 89% accuracy.

Abstract

Emotion modeling and recognition has drawn extensive attention from disciplines such as psychology, cognitive science, and, lately, engineering. Although a significant amount of research has been done on behavioral modalities, less explored characteristics include the physiological signals. This work brings to the table the ECG signal and presents a thorough analysis of its psychological properties. The fact that this signal has been established as a biometric characteristic calls for subject-dependent emotion recognizers that capture the instantaneous variability of the signal from its homeostatic baseline. A solution based on the empirical mode decomposition is proposed for the detection of dynamically evolving emotion patterns on ECG. Classification features are based on the instantaneous frequency (Hilbert-Huang transform) and the local oscillation within every mode. Two experimental setups are presented for the elicitation of active arousal and passive arousal/valence. The results support the expectations for subject specificity, as well as demonstrating the feasibility of determining valence out of the ECG morphology (up to 89 percent for 44 subjects). In addition, this work differentiates for the first time between active and passive arousal, and advocates that there are higher chances of ECG reactivity to emotion when the induction method is active for the subject.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Agrafioti et al. (2011) studied Emotion detection (n=44). ECG pattern analysis using empirical mode decomposition was evaluated on Determining emotional valence from ECG morphology. ECG pattern analysis using empirical mode decomposition demonstrated the feasibility of determining emotional valence from ECG morphology, achieving up to 89% accuracy in 44 subjects.

synapsesocial.com/papers/6a09e9dd00274e073d45c5d6https://doi.org/10.1109/t-affc.2011.28
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Medical biometrics: The perils of ignoring time dependency2009 · 33 citations
  2. 2Code Tracking Algorithms for Mitigating Multipath Effects in Fading Channels for Satellite-Based Positioning2007 · 80 citations
  3. 3Autonomic Nervous System Activity Distinguishes Among Emotions1983 · 2,712 citations
  4. 4PR and PP ECG intervals as indicators of autonomic nervous innervation of the cardiac sinoatrial and atrioventricular nodes2003 · 13 citations
  5. 5RT and systolic blood pressure variability after sympathetic stimulation during positive tilt in healthy volunteers2002 · 9 citations