PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 1, 1993Applied and Environmental Microbiology285 citationsOpen Access

Detection of enteroviruses in groundwater with the polymerase chain reaction

MAMorteza AbbaszadeganMHMary S. HuberCGCharles P. Gerba

Key Result

Treatment of groundwater concentrates with Sephadex G-100 and Chelex-100 effectively removed PCR-inhibitory factors, allowing successful detection of enteroviruses by RNA-PCR.

Structured PICO

P
Population
Groundwater concentrates and humic acid solutions seeded with poliovirus type 1
I
Intervention
Treatment with Sephadex G-100 in combination with Chelex-100 followed by RNA-PCR assay
C
Comparator
Treatment with Sephadex G-50, Sephadex G-200, Chelex-100 resin alone, or a mixed bed resin
O
Outcome
Detection of enteroviruses by RNA-PCR assaysurrogate

Treatment with Sephadex G-100 and Chelex-100 effectively removes PCR inhibitors from groundwater, enabling the rapid detection of enteroviruses via RNA-PCR.

Abstract

Standard methods for the detection of enteroviruses in environmental samples involve the use of cell culture, which is expensive and time-consuming. The polymerase chain reaction (PCR) is an attractive method for the detection of enteroviruses in water because primary cell culture is not needed and the increased sensitivity of PCR allows detection of the low numbers of target DNAs and RNAs usually found in environmental samples. However, environmental samples often contain substances that inhibit PCR amplification of target DNA and RNA. Procedures that remove substances that interfere with the amplification process need to be developed if PCR is to be successfully applied to environmental samples. An RNA-PCR assay for the detection of enteroviruses in water was developed and used to test a variety of groundwater concentrates and humic acid solutions seeded with poliovirus type 1. The groundwater samples and humic acid solutions were treated with Sephadex G-50, Sephadex G-100, Sephadex G-200, Chelex-100 resin, and a mixed bed resin to remove PCR-inhibitory material from the samples. Sephadex G-100 in combination with Chelex-100 was found to be very effective in removing inhibitory factors for the detection of enteroviruses in groundwater concentrates by PCR. Viruses were detected in two of the groundwater concentrates by the RNA-PCR assay after treatment with Sephadex G-100 plus Chelex-100. This was confirmed by tissue culture, suggesting that the treatment protocol and, subsequently, the RNA-PCR assay are applicable for the detection of enteroviruses in environmental samples.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Abbaszadegan et al. (1993) studied Enterovirus detection in groundwater. RNA-PCR assay after treatment with Sephadex G-100 plus Chelex-100 was evaluated on Detection of enteroviruses. Treatment of groundwater concentrates with Sephadex G-100 and Chelex-100 effectively removed PCR-inhibitory factors, allowing successful detection of enteroviruses by RNA-PCR.

synapsesocial.com/papers/6a0aa284c2fd2491b670a333https://doi.org/10.1128/aem.59.5.1318-1324.1993
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Polymerase Chain Reaction for Human Picornaviruses1989 · 226 citations
  2. 2Rapid method for processing soil samples for polymerase chain reaction amplification of specific gene sequences1991 · 124 citations
  3. 3Comparative Sensitivity of Various Cell Culture Systems for Isolation of Viruses from Wastewater and Fecal Samples1978 · 71 citations
  4. 4Health aspects of groundwater pollution.1994 · 36 citations
  5. 5Comparative sequence analysis of the 5′ noncoding region of the enteroviruses and rhinoviruses1988 · 191 citations