May 19, 2026Journal of Irrigation and Drainage Engineering0 citations

Field Calibration of Flow over Tilting Weirs in Canals

View Full Paper
JPJoseph E. PughTGTimothy K. GatesSVS. Karan Venayagamoorthy

Key Points

  • The aim is to adapt laboratory-based ratings for tilting weirs to real-world field conditions to improve irrigation outcomes.
  • Analyzed data from five tilting weir structures across three canal systems
  • Used a field correction factor (KF) to adjust lab-based discharge equations
  • Evaluated both lined and unlined channels with varying discharge rates from 0.35 to 15 m3/s.
  • Average KF value was 0.92, showing an 8% reduction from laboratory conditions.
  • Achieved mean absolute percentage errors of approximately ±6.2% in discharge measurements.
  • Demonstrated effective regulatory and measurement capabilities of tilting weirs in varied channel conditions.

Abstract

Tilting weirs are widely used to regulate water levels in open channel irrigation systems and can also provide flow measurement capability that helps optimize irrigation efficiency and ensure equitable water distribution. This case study demonstrates adaptation of lab-based tilting weir ratings to field settings, where flow behavior is more complex. We compile and analyze an extensive data set derived from independent studies of five structures within three canal systems, featuring both lined and unlined channels with discharge ranging from 0.35 to 15 m3/s (12 to 530 ft3/s). Results indicate that lab-based rating equations can be calibrated to account for site-specific variations (channel roughness, flow separation, etc.) using a field correction factor, KF, applied to the discharge coefficient in the rating equation. The average KF value across the seven data sets was 0.92, an 8% reduction from the laboratory. The case study demonstrates that tilting weirs can serve multiple purposes in the field, offering both stage regulation and discharge measurement with mean absolute percentage errors of approximately ±6.2%. Guidelines are given for optimizing tilting weir performance within engineered canals and additional research needs are identified for addressing complex natural channels.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Pugh et al. (2026) studied this question.

synapsesocial.com/papers/6a0bfdc7166b51b53d3790c1https://doi.org/10.1061/jidedh.ireng-10615
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Reimagining flow measurement with CFD: accuracy for non-standard hydraulic structures2026
  2. 2Discharge Formula and Hydraulics of Rectangular Side Weirs in the Small Channel and Field Inlet2024 · 6 citations
  3. 3CFD simulation model and experimental study to implement a new flowrate formula for a rounded broad crested weir considering the end depth as control section2020
  4. 4The calibration of sharp-crested weirs with a horizontal edge used for measuring flows in partially full pipes2024 · 1 citations
  5. 5The Hydraulic Performance Evaluation of a Compound Sharp Crested Weir with a Modified Trapezoidal–Semicircular Configuration2025