November 26, 2014Frontiers in Physiology77 citationsOpen Access

Role of sinoatrial node architecture in maintaining a balanced source-sink relationship and synchronous cardiac pacemaking

SUSathya D. UnudurthiRWRoseanne M. WolfTHThomas J. Hund

Key Result

The structural architecture of the sinoatrial node is critical for maintaining the source-sink balance required for normal pacemaking, with implications for biological pacemaker therapies.

PICO

P
Population
Sinoatrial node dysfunction

Abstract

Normal heart rhythm (sinus rhythm) depends on regular activity of the sinoatrial node (SAN), a heterogeneous collection of specialized myocytes in the right atrium. SAN cells, in general, possess a unique electrophysiological profile that promotes spontaneous electrical activity (automaticity). However, while automaticity is required for normal pacemaking, it is not necessarily sufficient. Less appreciated is the importance of the elaborate structure of the SAN complex for proper pacemaker function. Here, we review the important structural features of the SAN with a focus on how these elements help manage a precarious balance between electrical charge generated by the SAN ("source") and the charge needed to excite the surrounding atrial tissue ("sink"). We also discuss how compromised "source-sink" balance due, for example to fibrosis, may promote SAN dysfunction, characterized by slow and/or asynchronous pacemaker activity and even failure, in the setting of cardiovascular disease (e.g., heart failure, atrial fibrillation). Finally, we discuss implications of the "source-sink" balance in the SAN complex for cell and gene therapies aimed at creating a biological pacemaker as replacement or bridge to conventional electronic pacemakers.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Unudurthi et al. (2014) conducted a review in Sinoatrial node dysfunction. The structural architecture of the sinoatrial node is critical for maintaining the source-sink balance required for normal pacemaking, with implications for biological pacemaker therapies.