January 1, 1989European Journal of Cardio-Thoracic Surgery7 citations

Aortic valve replacement with frozen irradiated homografts An 18-year experience

View Full Paper
GCGianfranco CampalaniJCJoanne R ChalmersEWEdward M. Weaver

Key Result

Aortic valve replacement using frozen irradiated homografts had 8.8% early mortality, 49.6% late mortality over 5-18 years, and a 40% re-operation rate for homograft failure.

Study Design

Type

Observational (n=307)

Multicenter

No

Structured PICO

What are the long-term mortality and re-operation rates following isolated aortic valve replacement with frozen irradiated homografts?

P
Population
339 patients (307 with long-term follow-up) undergoing isolated aortic valve replacement. Mean age 53 (range 10-75), 234 males and 73 females. Dominant lesions included aortic stenosis (63.5%), aortic regurgitation (22.1%), and mixed aortic valve disease (14.3%).
I
Intervention
Isolated aortic valve replacement using frozen irradiated homografts, performed by a single surgeon using the same technique.
C
Comparator
Historical/external comparison with other major series using antibiotic sterilized homograft valves.
O
Outcome
Early mortality, late mortality, and re-operation for homograft failure.hard clinical

Long-term follow-up of frozen irradiated homografts for aortic valve replacement reveals high rates of late mortality and homograft failure requiring re-operation.

Limitations

  • Thirty-two patients were lost to follow-up at various stages
  • 32 patients were lost to follow-up

Abstract

Between May 1968 and April 1981, 339 patients underwent isolated aortic valve replacement using frozen irradiated homografts. All the operations were carried out by the same surgeon (EJMW) using the same technique. Thirty-two patients were lost to follow-up at various stages and the long-term results of the remaining 307 patients are reported. Two hundred and thirty-four were males and 73 females. Their ages ranged between 10 and 75 years, with a mean age of 53. The dominant lesion was aortic stenosis in 195 cases (63.5%), aortic regurgitation in 68 (22.1%), and mixed aortic valve disease in 44 (14.3%). Early mortality was 8.8% and late mortality during the 5-18 year follow-up period was 49.6%. Re-operations for homograft failure were carried out in 112 patients (40%), with an early mortality of 25%. The results are compared with those of other major series using antibiotic sterilized homograft valves.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Campalani et al. (1989) conducted an observational in Aortic valve disease (n=307). Frozen irradiated homografts was evaluated on Late mortality. Aortic valve replacement using frozen irradiated homografts had 8.8% early mortality, 49.6% late mortality over 5-18 years, and a 40% re-operation rate for homograft failure.

synapsesocial.com/papers/6a0ccbd5291fe4aa62625582https://doi.org/10.1016/1010-7940(89)90119-x
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Homograft aortic valve replacement: seven years' experience with antibiotic-treated valves.1981 · 47 citations
  2. 2Aortic Homograft Valve Replacement1969 · 115 citations
  3. 3Six year review of the results of freehand aortic valve replacement using an antibiotic sterilized homograft valve.1977 · 108 citations
  4. 4Replacement of Diseased Aortic Valves with Homografts1969 · 34 citations
  5. 5Radiology of homograft aortic valves1969 · 32 citations