PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 2019Physiological Reports17 citationsOpen Access

GsMTx4 reduces the reflex pressor response during dynamic hindlimb skeletal muscle stretch in decerebrate rats

View Full Paper
BSBailey C. SandersonKRKorynne S. RollinsTHTyler D. Hopkins

Key Result

Injection of 10 μg of GsMTx4 reduced the peak pressor response during dynamic hindlimb muscle stretch compared to control (5 vs 15 mmHg, P < 0.05) in decerebrate rats.

Structured PICO

Does GsMTx4 reduce the pressor response during dynamic hindlimb skeletal muscle stretch in decerebrate rats?

P
Population
Decerebrate, unanesthetized rats (n=8)
I
Intervention
Injection of 10 μg of GsMTx4 into the arterial supply of a hindlimb during a 30 sec, 1 Hz dynamic hindlimb muscle stretch protocol
C
Comparator
Control
O
Outcome
Peak pressor response and pressor response at multiple time points throughout the duration of the stretchsurrogate

GsMTx4 reduces the reflex pressor response during dynamic muscle stretch, indicating that GsMTx4-sensitive channels contribute to the mechanoreflex by responding to changes in muscle length.

Main Result

Absolute Event Rate: 5% vs 15%

p-value: p=<0.05

Abstract

Mechanical signals within contracting skeletal muscles contribute to the generation of the exercise pressor reflex; an important autonomic and cardiovascular control mechanism. In decerebrate rats, the mechanically activated channel inhibitor GsMTx4 was found to reduce the pressor response during static hindlimb muscle stretch; a maneuver used to investigate specifically the mechanical component of the exercise pressor reflex (i.e., the mechanoreflex). However, the effect was found only during the initial phase of the stretch when muscle length was changing and not during the later phase of stretch when muscle length was relatively constant. We tested the hypothesis that in decerebrate, unanesthetized rats, GsMTx4 would reduce the pressor response throughout the duration of a 30 sec, 1 Hz dynamic hindlimb muscle stretch protocol that produced repetitive changes in muscle length. We found that the injection of 10 μg of GsMTx4 into the arterial supply of a hindlimb reduced the peak pressor response (control: 15 ± 4, GsMTx4: 5 ± 2 mmHg, P < 0.05, n = 8) and the pressor response at multiple time points throughout the duration of the stretch. GsMTx4 had no effect on the pressor response to the hindlimb arterial injection of lactic acid which indicates the lack of local off-target effects. Combined with the recent finding that GsMTx4 reduced the pressor response only initially during static stretch in decerebrate rats, the present findings suggest that GsMTx4-sensitive channels respond primarily to mechanical signals associated with changes in muscle length. The findings add to our currently limited understanding of the channels that contribute to the activation of the mechanoreflex.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Sanderson et al. (2019) studied Exercise pressor reflex (n=8). GsMTx4 vs. Control was evaluated on Peak pressor response (p=<0.05). Injection of 10 μg of GsMTx4 reduced the peak pressor response during dynamic hindlimb muscle stretch compared to control (5 vs 15 mmHg, P < 0.05) in decerebrate rats.

synapsesocial.com/papers/6a0d765ececdf5fb20ba78a1https://doi.org/10.14814/phy2.13974
Ask AI
Helpful
Bookmark
Share
View Full Paper