January 1, 1985Radiology55 citations

Gated cardiac magnetic resonance structural imaging: optimization by electronic axial rotation.

View Full Paper
DFD H FeiglinCGC. R. P. GeorgeWMW J MacIntyre

Key Result

Electronic axial rotation of magnetic fields improved visualization of cardiac structures and allowed more accurate estimates of chamber size and myocardial mass compared to body orthogonal axes.

Structured PICO

Does electronic angulation of magnetic fields improve visualization of cardiac structures compared to standard body orthogonal axes in cardiac MRI?

P
Population
Subjects undergoing cardiac magnetic resonance imaging
I
Intervention
Electronic angulation of the magnetic fields to align with short and long cardiac axes
C
Comparator
Standard body orthogonal axes (Z axis along body length, X and Y at right angles)
O
Outcome
Visualization of cardiac structural detail and functional statussurrogate

Electronic axial rotation in cardiac MRI improves the visualization of cardiac structures and the accuracy of chamber size and mass estimates compared to standard body orthogonal axes.

Abstract

Most magnetic resonance imaging has used body orthogonal axes with the Z axis placed along the length of the body and the X and Y axes at right angles to the body. This orientation is not optimum for the heart; visualization of sections along the short and long cardiac axes would best define cardiac structural detail and functional status. The new orientation was accomplished by selection of electronic angulation of the magnetic fields for each subject rather than by attempting to approximate the cardiac axes by altering the position of the patient. This technique improved visualization of comparative wall segments, valvular structures, and the true four-chamber view of the heart, and also gave the best visualization of the pericardium. In addition, more accurate estimates of chamber size and myocardial mass can be made from the short-axis orientation, since the sections are orthogonal to the myocardium.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Feiglin et al. (1985) studied Cardiac structural imaging. Electronic axial rotation of magnetic fields vs. Body orthogonal axes was evaluated on Visualization of cardiac structural detail and functional status. Electronic axial rotation of magnetic fields improved visualization of cardiac structures and allowed more accurate estimates of chamber size and myocardial mass compared to body orthogonal axes.

synapsesocial.com/papers/6a0dd0dc1e1a6dfdb4bad8edhttps://doi.org/10.1148/radiology.154.1.3155478