July 1, 2020JACC. Clinical electrophysiology78 citationsOpen Access

Electrocardiographic Analysis for His Bundle Pacing at Implantation and Follow-Up

HBHaran BurriMJMarek JastrzębskiPVPugazhendhi Vijayaraman

Key Result

This review provides practical guidance on using and troubleshooting the 12-lead electrocardiogram to confirm capture of conduction tissue during His bundle pacing in clinical practice.

Key Points

  • To provide practical guidance for interpreting the electrocardiogram (ECG) in the context of His bundle pacing (HBP).
  • Review of literature on electrocardiographic analysis for HBP
  • Identification of key ECG features for successful HBP
  • Troubleshooting strategies for common ECG interpretation challenges
  • HBP is effective for physiological cardiac stimulation when conduction tissue capture is confirmed via ECG analysis.
  • Challenges in ECG interpretation require careful consideration for successful HBP implementation.
  • Practical guidance on 12-lead ECG use is crucial for clinicians in daily practice.

Structured PICO

I
Intervention
12-lead ECG analysis for His bundle pacing

Provides practical guidance on using and troubleshooting the 12-lead ECG for His bundle pacing at implantation and follow-up.

Abstract

His bundle pacing (HBP) is steadily gaining interest for providing physiological cardiac stimulation. Careful analysis of the electrocardiogram (ECG) is crucial to confirm capture of conduction tissue, which is a prerequisite for successful HBP at implantation and follow-up. However, interpretation of the ECG with HBP can be challenging. This review provides the reader with practical guidance on how to best use and troubleshoot the 12-lead ECG for HBP in daily clinical practice.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Burri et al. (2020) conducted a review in His bundle pacing. Electrocardiographic analysis was evaluated. This review provides practical guidance on using and troubleshooting the 12-lead electrocardiogram to confirm capture of conduction tissue during His bundle pacing in clinical practice.

synapsesocial.com/papers/6a0e97b38561d4cf804c50a0https://doi.org/10.1016/j.jacep.2020.03.005