May 10, 2022International Journal of Environmental Research and Public Health5 citationsOpen Access

Safety and Effectiveness of Transvenous Lead Extraction in Patients with Infected Cardiac Resynchronization Therapy Devices; Is It More Risky than Extraction of Other Systems?

View Full Paper
PSPaweł StefańczykDNDorota NowosieleckaAPAnna Polewczyk

Key Result

Transvenous lead extraction of infected CRT systems showed similar procedural success and complication rates to pacemaker extraction, despite higher >1-year mortality (22.7% vs 8.7%).

Study Design

Type

Cohort (n=3,468)

Multicenter

No

Structured PICO

Does transvenous lead extraction of infected CRT systems increase procedural risk compared to extraction of other infected CIED systems in patients with device infections?

P
Population
3,468 patients undergoing transvenous lead extraction (TLE), including a subset of 1,138 patients with infectious indications (150 with infected CRT devices, alongside pacemaker and ICD patients).
I
Intervention
Transvenous lead extraction of infected cardiac resynchronization therapy (CRT) systems
C
Comparator
Transvenous lead extraction of infected pacemakers (PM) and implantable cardioverter defibrillator (ICD) systems
O
Outcome
Safety (major complications, procedure-related death) and effectiveness (clinical and procedural success)safety

Transvenous lead extraction of infected CRT systems is as safe and effective as extraction of other CIEDs, with procedural complexity driven more by implant duration than device type.

Main Result

Absolute Event Rate: 22.7% vs 8.7%

Abstract

Background: Transvenous lead extraction (TLE) in patients with implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices is considered as more risky. The aim of this study was to assess the safety and effectiveness of TLE in patients with infected CRT systems. Methods: Data of 3468 patients undergoing TLE in a single high-volume center in years 2006−2021 were analyzed. The clinical and procedural parameters as well as the efficacy and safety of TLE were compared between patients with infected CRT and pacemakers (PM) and ICD systems. Results: Infectious indications for TLE occurred in 1138 patients, including 150 infected CRT (112 CRT-D and 38 CRT-P). The general health condition of CRT patients was worse with higher Charlson’s comorbidity index. The number of extracted leads was higher in the CRT group, but implant duration was significantly longer in the PM than in the ICD and CRT groups (98.93 vs. 55.26 vs. 55.43 months p < 0.01). The procedure was longer in duration, more difficult, and more complex in patients with pacemakers than in those in the CRT group. The occurrence of major complications and clinical and procedural success as well as procedure-related death did not show any relationship to the type of CIED device. Mortality at more than one-year follow-up after TLE was significantly higher among patients with CRT devices (22.7% vs. 8.7%) than among those in the PM group. Conclusion: Despite the greater burden of lead and comorbidities, the complexity and efficiency of removing infected CRT systems is no more dangerous than removing other infected systems. The duration of the implant seems to play a dominant role.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Stefańczyk et al. (2022) conducted a cohort in Infected cardiac resynchronization therapy (CRT) devices (n=3,468). Transvenous lead extraction of infected CRT systems vs. Extraction of infected pacemakers (PM) and ICD systems was evaluated on Mortality at more than one-year follow-up. Transvenous lead extraction of infected CRT systems showed similar procedural success and complication rates to pacemaker extraction, despite higher >1-year mortality (22.7% vs 8.7%).