PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 18, 2010Heart62 citations

Long-term efficacy of catheter ablation for atrial fibrillation: impact of additional targeting of fractionated electrograms

View Full Paper
RHRoss J. HunterTBThomas BerrimanIDIhab Diab

Key Result

Additional targeting of complex or fractionated electrograms during catheter ablation improved outcomes for persistent atrial fibrillation after the first cluster of procedures (p=0.049).

Key Points

  • To assess the long-term efficacy of catheter ablation for atrial fibrillation and evaluate the impact of adjunctive complex fractionated electrogram targeting in persistent atrial fibrillation.
  • Analyzed prospective registry data from 285 consecutive patients (mean age 57 years; 53% paroxysmal AF, 47% persistent AF) who underwent 530 ablation procedures between 2002 and 2007.
  • All patients underwent wide-area circumferential ablation; persistent AF patients received additional linear lesions, with complex fractionated electrogram (CFE) targeting added from 2005 onward, over a mean follow-up of 2.7 years (0.2–7.4 years).
  • Long-term freedom from AF/atrial tachyarrhythmia was 86% for paroxysmal AF and 68% for persistent AF, with late recurrence occurring at 3 per 100 years of follow-up after 3 years.
  • Targeting CFEs significantly improved outcomes for persistent AF after the initial procedure cluster (p=0.049), with a trend toward improved final outcome (p=0.130).
  • Procedural stroke/TIA occurred in 0.6% and pericardial effusion requiring drainage in 1.7%, while late stroke/TIA incidence was 0.3% per year.

Study Design

Type

Cohort (n=285)

Structured PICO

Does additional targeting of complex or fractionated electrograms during catheter ablation improve long-term freedom from atrial fibrillation in patients with persistent AF?

P
Population
285 consecutive patients with atrial fibrillation (53% paroxysmal, 47% persistent), mean age 57, 75% male, 20% with structural heart disease.
I
Intervention
Catheter ablation (wide-area circumferential ablation with confirmation of electrical isolation). For persistent AF, linear lesions were added, with additional targeting of complex or fractionated electrograms (CFE) from 2005.
C
Comparator
For persistent AF, ablation without targeting of CFE (historical control before 2005).
O
Outcome
Long-term freedom from AF/atrial tachyarrhythmia

Catheter ablation provides long-term freedom from AF in most patients, and additional targeting of fractionated electrograms improves outcomes specifically in persistent AF.

Main Result

p-value: p=0.049

Abstract

OBJECTIVES: To investigate long-term efficacy of catheter ablation for atrial fibrillation (AF) and the impact of ablating complex or fractionated electrograms (CFEs) in addition to pulmonary vein isolation and linear lesions in persistent AF (PeAF). METHODS: Consecutive cases from 2002-2007 were analysed. All the patients underwent a wide-area circumferential ablation with confirmation of electrical isolation. For PeAF, linear lesions were added, with additional targeting of CFE from 2005. Data were collected in a prospective database. Attempts were made to contact all patients for follow-up. RESULTS: 285 patients underwent 530 procedures. The mean (SD) age was 57 (11) years, 75% were male, 20% had structural heart disease and 53% had paroxysmal AF (PAF). The mean number of procedures was 1.9 per patient (1.7 for PAF and 2.0 for PeAF). Procedural complications included stroke or transient ischemic attack in 0.6% and pericardial effusion requiring drainage in 1.7%. During 2.7 years (0.2 to 7.4 years) of follow-up from the last procedure, there were seven deaths (unrelated to their ablation or AF) and three strokes or transient ischemic attack (0.3% per year). Freedom from AF/atrial tachyarrhythmia was 86% for PAF and 68% for PeAF. Late recurrence was 3 per 100 years of follow-up after >3 years. The Kaplan-Meier analysis showed that CFE ablation improved the outcome for PeAF after the first cluster of procedures (p=0.049), with a trend towards improved final outcome (p=0.130). CONCLUSIONS: Long-term freedom from AF is achievable in most patients with PAF and PeAF with low rates of late recurrence. Additional targeting of CFE improves outcome for PeAF. Late adverse events including stroke are few.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hunter et al. (2010) conducted a cohort in Atrial fibrillation (n=285). Catheter ablation with additional targeting of complex or fractionated electrograms (CFEs) vs. Catheter ablation without CFE targeting was evaluated on Outcome for persistent AF after the first cluster of procedures (p=0.049). Additional targeting of complex or fractionated electrograms during catheter ablation improved outcomes for persistent atrial fibrillation after the first cluster of procedures (p=0.049).

synapsesocial.com/papers/6a0f024d53f874f2b2230fffhttps://doi.org/10.1136/hrt.2009.188128
Ask AI
Helpful
Bookmark
Share
View Full Paper