Echocardiographic assessment of left ventricular filling pressure compared to pulmonary artery catheter in mechanically ventilated patients: Systematic review and meta-analysis

View Full Paper
MCMargherita CalicchiaVBValeria BianchiACAlberto Calabrese

Key Result

Doppler echocardiography (lateral E/E') correlated with pulmonary artery occlusion pressure for assessing left ventricular filling pressure (pooled correlation coefficient 0.72; 95% CI 0.52-0.92).

Study Design

Type

Meta-Analysis (n=696)

Structured PICO

Does Doppler echocardiography accurately predict left ventricular filling pressure compared to pulmonary artery catheter in mechanically ventilated critically ill patients?

P
Population
18 prospective studies (n = 696 patients) of critically ill patients undergoing mechanical ventilation in the ICU.
I
Intervention
Assessment of left ventricular filling pressures (LVFP) using transthoracic or transesophageal Doppler echocardiography.
C
Comparator
Pulmonary artery occlusion pressure (PAOP) measurement obtained via a pulmonary artery catheter.
O
Outcome
Accuracy of echocardiographic measurements and their correlation with PAOP.surrogate

Doppler echocardiography shows potential for assessing left ventricular filling pressures in mechanically ventilated critically ill patients, though current evidence is limited by small sample sizes and high heterogeneity.

Main Result

Effect estimate: Pooled correlation coefficient 0.72 for lateral E/E' (95% CI 0.52-0.92)

Limitations

  • Small sample sizes
  • Study heterogeneity
  • Use of different PAOP cut-off values to define elevated LVFP
  • small sample sizes
  • study heterogeneity
  • use of different PAOP cut-off values to define elevated LVFP

Abstract

Background: Estimating left ventricular filling pressures (LVFP) is a crucial component of hemodynamic monitoring in critically ill patients. While non-invasive techniques such as Doppler echocardiography have been validated in non-critical populations, their application in mechanically ventilated patients remains less well-documented. Objective: This study aims to evaluate the accuracy of Doppler echocardiography in predicting LVFP, as assessed by pulmonary artery occlusion pressure (PAOP), in mechanically ventilated patients admitted to the intensive care unit (ICU). Methods: We conducted a systematic review and meta-analysis of peer-reviewed studies focusing on critically ill patients undergoing mechanical ventilation in the ICU (Population-P). The intervention (I) was the assessment of LVFP using transthoracic or transesophageal echocardiography. The comparator (C) was PAOP measurement obtained via a pulmonary artery catheter. The primary outcomes (O) included the accuracy of echocardiographic measurements and their correlation with PAOP. We searched three databases (PubMed/Medline, Scopus, and Embase), screened relevant articles, synthesized the data, assessed study quality using standard tools, and graded the level of evidence with GRADE criteria. A meta-analysis was performed for comparable findings. Results: Of 3596 studies initially identified, 18 prospective studies (n = 696 patients) met the inclusion criteria, with 8 studies (n = 342 patients) included in the meta-analysis. All studies featured small sample sizes (less than 100 patients). Six studies evaluated E/A ratios, and four E/E' ratios. in relation to PAOP. The area under the receiver operating characteristic (AUROC) curve ranged from 0.69 to 0.83 for E/A and from 0.60 to 0.91 for lateral E/E' in predicting PAOP ≥ 18 mmHg. Both E/A and lateral E/E' showed a correlation with PAOP, with pooled correlation coefficients of 0.48 (95% confidence intervals CI: 0.48-0.58) and 0.72 (95% CI: 0.52-0.92), respectively. Study quality ranged from low to high and heterogeneity was high the overall level of evidence was deemed very low. Conclusions: Doppler echocardiography shows potential for assessing LVFP in critically ill patients on mechanical ventilation. However, limitations such as small sample sizes and study heterogeneity, including the use of different PAOP cut-off values to define elevated LVFP, highlight the need for further research to strengthen its role in this setting.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Calicchia et al. (2026) conducted a meta-analysis in Critically ill patients undergoing mechanical ventilation (n=696). Doppler echocardiography vs. Pulmonary artery catheter (PAOP) was evaluated on Accuracy of echocardiographic measurements and their correlation with PAOP (Pooled correlation coefficient 0.72 for lateral E/E', 95% CI 0.52-0.92). Doppler echocardiography (lateral E/E') correlated with pulmonary artery occlusion pressure for assessing left ventricular filling pressure (pooled correlation coefficient 0.72; 95% CI 0.52-0.92).

synapsesocial.com/papers/6a0ffded5725bbd5cc6059abhttps://doi.org/10.1016/j.aicoj.2025.100024
Ask AI
Helpful
Bookmark
Share
View Full Paper