April 1, 1986Ultrasonic Imaging327 citations

Time Domain Formulation of Pulse-Doppler Ultrasound and Blood Velocity Estimation by Cross Correlation

View Full Paper
OBOdile BonnefousPPP. Pesqué

Structured PICO

P
Population
Computer-simulated data of a cloud of moving targets
I
Intervention
Time domain formulation using cross-correlation of received rf signals for velocity estimation
C
Comparator
Traditional phase-shift based velocity estimators (pulse-Doppler)
O
Outcome
Accuracy of velocity profiles and overcoming classical velocity limitationsurrogate

A novel time domain cross-correlation technique for pulse-Doppler ultrasound overcomes classical velocity limitations, potentially enabling more reliable quantitative blood flow mapping.

Abstract

The Doppler effect is usually described as a frequency shift of the backscattered signals from moving targets with respect to the frequency transmitted. Recently, real-time blood flow imaging has become possible thanks to the development of a new velocity estimator based on phase-shift measurements of successive echoes. However, this method suffers from the well-known limitations of pulse-Doppler instruments. A new formulation is presented which describes the pulse-Doppler effect on the successive echoes from a cloud of moving targets as a progressive translation in time due to the displacement of the scatterers between two excitations. This approach allows us to generate efficiently computer-simulated data in order to evaluate accurately the various processing techniques. Furthermore, it leads to a novel class of velocity estimators in the time domain which measure the time shifts which are proportional to the local blood velocity. Among them, the cross correlation of the received rf signals turns out to be well suited. A local cross-correlation function is first calculated from a consecutive pair of range-gated echoes and the time shift is then determined by searching for the time position with the maximum correlation. The time-correlation technique is shown to provide accurate velocity profiles with broadband transducers. Moreover, the classical velocity limitation of pulse-Doppler is overcome because there is no ambiguity in measuring a time shift instead of a phase shift. These major advantages should make quantitative flow mapping possible and more reliable.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bonnefous et al. (1986) studied this question.

synapsesocial.com/papers/6a10954c4fb650da4fffadfbhttps://doi.org/10.1177/016173468600800201
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Real-Time Spectrum Analysis and Display of Directional Doppler Ultrasound Blood Velocity Signals1980 · 22 citations
  2. 2A Multigate Pulsed Doppler System with Serial Data Processing1981 · 68 citations
  3. 3Ultrasonic Doppler Method for the Inspection of Cardiac Functions1957 · 229 citations
  4. 4The generalized correlation method for estimation of time delay1976 · 4,425 citations
  5. 5Pulsed Ultrasonic Doppler Blood-Flow Sensing1970 · 373 citations