PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 1, 2000Journal of Magnetic Resonance Imaging54 citationsOpen Access

Application of breath-hold T2-weighted, first-pass perfusion and gadolinium-enhanced T1-weighted MR imaging for assessment of myocardial viability in a pig model

View Full Paper
SCSang Il ChoiCJChun Zi JiangKLKeun Ho Lim

Key Result

T2-weighted and Gd-enhanced T1-weighted MR imaging overestimated infarct size compared to TTC staining (34.7% and 32.3% vs 28.3%; P<0.05), whereas first-pass perfusion images correlated well.

Structured PICO

Does MR imaging accurately assess myocardial viability compared to TTC staining in a pig model of reperfused myocardial infarction?

P
Population
Pig model of reperfused myocardial infarction
I
Intervention
T2-weighted, first-pass perfusion, and delayed gadolinium-enhanced T1-weighted MR imaging
C
Comparator
2,3,5-triphenyltetrazolium chloride (TTC) staining and electron microscopic examination
O
Outcome
Correlation of abnormal signal area on MR images to the infarct area on pathologic examinationsurrogate

First-pass perfusion MR imaging accurately reflects infarct areas, whereas T2-weighted and Gd-enhanced T1-weighted images overestimate infarct size by including peri-infarct areas in a pig model.

Main Result

Absolute Event Rate: 34.7% vs 28.3%

p-value: p=<0.05

Abstract

The purpose of this study was to correlate the abnormal signal area on various magnetic resonance (MR) images to the infarct area on pathologic examination and to assess the myocardial viability on the basis of MR images. T2-weighted, first-pass perfusion, and delayed gadolinium-enhanced T1-weighted images were used as "one-stop examinations" in a pig model of reperfused myocardial infarction. The results of each MR image were compared with those of 2,3, 5-triphenyltetrazolium chloride (TTC) staining. The abnormal signal areas on T2-weighted and Gd-enhanced T1-weighted images were larger than the infarct areas on TTC staining (34.7% and 32.3% vs. 28.3%; P< 0.05), whereas the nonperfused areas on perfusion images were correlated (25.6% vs, 28.3%; P = 0.139). Electron microscopic examination showed severely distorted ultrastructures in the infarct areas and mildly damaged ultrastructures in the peri-infarct areas. Perfusion images probably reflected the infarct areas, whereas T2-weighted and Gd-enhanced T1-weighted images seemed to include peri-infarct as well as infarct areas.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Choi et al. (2000) studied Reperfused myocardial infarction. Magnetic resonance imaging (T2-weighted, first-pass perfusion, Gd-enhanced T1-weighted) vs. 2,3,5-triphenyltetrazolium chloride (TTC) staining was evaluated on Abnormal signal area compared to infarct area on pathologic examination (p=<0.05). T2-weighted and Gd-enhanced T1-weighted MR imaging overestimated infarct size compared to TTC staining (34.7% and 32.3% vs 28.3%; P<0.05), whereas first-pass perfusion images correlated well.

synapsesocial.com/papers/6a123ef2c031bb6829a62d87https://doi.org/10.1002/(sici)1522-2586(200005)11:5<476::aid-jmri2>3.0.co;2-5
Ask AI
Helpful
Bookmark
Share
View Full Paper