Distal Anchor Balloon Technique to Facilitate Transcatheter Aortic Valve Delivery—A Case Report

View Full Paper
SLSasa LoncarVVVojislav VukašinovićNMNikola Malešević

Key Result

The use of a distal anchor balloon (20/45 mm) over a buddy wire successfully facilitated guidewire compression and transcatheter aortic valve advancement in a challenging anatomical case.

Key Points

  • This report highlights a novel technique to enhance transcatheter aortic valve delivery in cases with anatomical obstacles.
  • Describes a case involving a surgical tissue prosthesis with Dacron conduit.
  • Utilized a 20/45 mm anchor balloon to assist in guidewire compression.
  • Employed a buddy wire for effective valve advancement.
  • Successfully delivered a bulky prosthesis through a constricted surgical bioprosthetic valve.
  • Anchor balloon facilitated smoother navigation of the delivery system through the aortic arch.

Study Design

Type

Case Report (n=1)

Structured PICO

Does the distal anchor balloon technique facilitate transcatheter aortic valve delivery in patients with challenging anatomy such as a surgical tissue prosthesis with a Dacron conduit?

P
Population
A patient with severe aortic stenosis and a surgical tissue prosthesis with a Dacron conduit undergoing transcatheter aortic valve replacement (TAVR)
I
Intervention
Distal anchor balloon technique (20/45 mm balloon over a buddy wire)
O
Outcome
Successful prosthetic valve delivery and advancement

The distal anchor balloon technique can be a useful alternative strategy to facilitate transcatheter aortic valve delivery in challenging anatomies such as a surgical tissue prosthesis with a Dacron conduit.

Abstract

Transcatheter aortic valve replacement has been established as an advanced therapeutic modality for severe aortic stenosis. Despite procedural advancements, anatomical variations may hinder successful prosthetic valve delivery in certain cases. Delivering a relatively bulky prosthesis through a constricted and extensively stenosed surgical bioprosthetic valve remains challenging. Such cases require alternative procedural strategies to enable smooth device navigation. In this case, the presence of a surgical tissue prosthesis with a Dacron conduit resulted in stacking of the delivery system within the aortic arch. An anchor balloon (20/45 mm) over a buddy wire was used to assist in guidewire compression and effective valve advancement.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Loncar et al. (2026) conducted a case report in Severe aortic stenosis (n=1). Distal anchor balloon technique was evaluated on Effective valve advancement. The use of a distal anchor balloon (20/45 mm) over a buddy wire successfully facilitated guidewire compression and transcatheter aortic valve advancement in a challenging anatomical case.

synapsesocial.com/papers/6a13e8d20e02ee3982d336a6https://doi.org/10.1177/26324636261447979
Ask AI
Helpful
Bookmark
Share
View Full Paper