An Evaluation of Automated Indirect Blood Pressure Measurement During Pregnancy

View Full Paper
IMIan MilsomSSSofia SvahnLFLars Forssman

Structured PICO

Does the Dinamap automated indirect blood pressure instrument provide accurate and reproducible measurements compared to intra-arterial and manual methods in pregnant women?

P
Population
10 healthy women in the last trimester of pregnancy
I
Intervention
Automated indirect blood pressure measurement using the Dinamap instrument
C
Comparator
Intra-arterial blood pressure measurement and manual sphygmomanometry (auscultation)
O
Outcome
Accuracy and reproducibility of blood pressure measurements compared to intra-arterial and manual methodssurrogate

The Dinamap automated blood pressure instrument provides reliable and reproducible measurements of blood pressure changes during late pregnancy, eliminating inter-observer error.

Abstract

An automatic microcomputer-assisted instrument (Dinamap) for indirect determination of blood pressure was evaluated in 10 healthy women in the last trimester of pregnancy. Blood pressure determined intra-arterially was significantly (p less than 0.001) higher than indirect blood pressure determined with the Dinamap instrument or by manual sphygmomanometry. However, there was no significant difference in the mean change in blood pressure determined by the three techniques under investigation. A close correlation was recorded between systolic and diastolic blood pressure determined intra-arterially and with the Dinamap instrument (r = 0.92, r = 0.90), and between blood pressure determined intra-arterially and indirectly by auscultation (r = 0.93, r = 0.81). There was no significant difference in the reproducability of individual blood pressure values determined intra-arterially (systolic, 2.4 mmHg, diastolic, 3.7 mmHg) or by the Dinamap instrument (systolic, 2.8 mmHg, diastolic, 3.4 mmHg) or by auscultation (systolic, 5.0 mmHg, diastolic, 4.9 mm Hg). The Dinamap instrument proved reliable for the measurement of changes in blood pressure during late pregnancy. The technique eliminates the problem of inter-observer error which otherwise becomes evident when checking blood pressure antenatally.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Milsom et al. (1986) studied this question.

synapsesocial.com/papers/6a14b23a18abc81f8aa5ffb3https://doi.org/10.3109/00016348609161489