May 26, 2026Buildings0 citationsOpen Access

Analysis of Pollutant Dispersion in High-Rise Buildings Under Wind–Thermal Coupling

View Full Paper
XLXiaozhi LiuCSChongfang SongWPWuxuan Pan

Key Points

  • This study aims to analyze how thermal and wind conditions affect pollutant dispersion in high-rise buildings.
  • Conducted transient CFD simulations using field-measured wall temperatures and window wind velocities.
  • Investigated vertical diffusion of buoyant (CH4) and dense (CO2) pollutants in a high-rise residential building.
  • Analyzed the effects of thermal pressure, window velocity, and wind-thermal coupling.
  • Under wind-thermal coupling, pollutant diffusion rate is 200% faster than under thermal pressure alone.
  • CH4 shows 2–4 orders of magnitude higher concentrations and broader influence range compared to CO2.
  • Asymmetric diffusion patterns observed, with wind dominating the upper region and thermal effects in the lower.

Abstract

Controlling pollutant dispersion in high-rise buildings is crucial for public health. Vertical pollutant diffusion in stairwells occurs under thermal and wind effects. However, most existing studies rely on idealized boundary conditions. To address this, this study uses field-measured wall temperatures and a window wind velocity as boundary conditions for transient CFD simulations. We investigate the vertical diffusion characteristics of buoyant (CH4) and dense (CO2) pollutants under thermal pressure, window velocity, and wind–thermal coupling in a high-rise residential building in Taiyuan. Results show an asymmetric “fast-up, slow-down” diffusion under thermal pressure, a relatively symmetric profile under window velocity, and a hybrid pattern under coupling where the upper region is wind-dominated and the lower region resembles thermal-driven diffusion. Wind–thermal coupling most significantly enhances upward diffusion. Using the arrival time of CH4 at the 28th floor (about 15 m above the source floor) as the benchmark, the diffusion rate under coupling is about 200% faster than under thermal pressure alone, and about 50% faster than under the window-velocity condition alone. Differences in density lead to variations in dispersion, with CH4 exhibiting higher rates, concentrations (2–4 orders greater), and a broader influence range than CO2. This work interprets the synergistic regulatory mechanism between driving forces and pollutant density, providing a theoretical basis for ventilation optimization and pollution control in high-rise buildings.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Liu et al. (2026) studied this question.

synapsesocial.com/papers/6a153bdfb5d9c58d83e8d483https://doi.org/10.3390/buildings16112095
Ask AI
Helpful
Bookmark
Share
View Full Paper