PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 2003120 citations

A moving average based filtering system with its application to real-time QRS detection

View Full Paper
HCHung‐Chi ChenSCSzi-Wen Chen

Key Result

A novel real-time QRS detection algorithm based on a moving average filter correctly detected over 99.5% of QRS complexes from a subset of the MIT-BIH arrhythmia database.

Structured PICO

P
Population
Subset of the MIT-BIH arrhythmia database (standard ECG database)
I
Intervention
Novel real-time QRS detection algorithm based on a simple moving average filter
O
Outcome
Correct detection of QRS complexessurrogate

A novel, computationally simple moving average filter-based algorithm achieved >99.5% accuracy for real-time QRS detection on the MIT-BIH database.

Abstract

This paper presents a novel real-time QRS detection algorithm designed based on a simple moving average filter. The proposed algorithm demands no redundant preprocessing step, thus allowing a simple architecture for its implementation as well as low computational cost. Algorithm performance was validated against a subset of the MIT-BIH arrhythmia database. Consequently, numerical results showed that the proposed algorithm correctly detected over 99.5% of the QRS complexes from the standard ECG database, implying it may be considered as a simple and reliable candidate of QRS detection algorithms.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Chen et al. (2003) studied Arrhythmia. Moving average based filtering system for QRS detection was evaluated on QRS detection accuracy. A novel real-time QRS detection algorithm based on a moving average filter correctly detected over 99.5% of QRS complexes from a subset of the MIT-BIH arrhythmia database.

synapsesocial.com/papers/6a158373a2352da347828b84https://doi.org/10.1109/cic.2003.1291223
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A Real-Time QRS Detection Algorithm1985 · 7,849 citations
  2. 2Nonlinear transforms of ECG signals for digital QRS detection: a quantitative analysis1994 · 101 citations
  3. 3QRS Detection By Template Matching Using Real-Time Correlation On A Microcomputer1984 · 60 citations
  4. 4Automated High-Speed Analysis of Holter Tapes with Microcomputers1983 · 115 citations
  5. 5Neural-network-based adaptive matched filtering for QRS detection1992 · 422 citations