July 30, 2014Sensors46 citationsOpen Access

Tracheal Sounds Acquisition Using Smartphones

BRBersaín A. ReyesNRNataša ReljinKCKi H. Chon

Key Points

Key points are not available for this paper at this time.

Abstract

Tracheal sounds have received a lot of attention for estimating ventilation parameters in a non-invasive way. The aim of this work was to examine the feasibility of extracting accurate airflow, and automating the detection of breath-phase onset and respiratory rates all directly from tracheal sounds acquired from an acoustic microphone connected to a smartphone. We employed the Samsung Galaxy S4 and iPhone 4s smartphones to acquire tracheal sounds from N = 9 healthy volunteers at airflows ranging from 0.5 to 2.5 L/s. We found that the amplitude of the smartphone-acquired sounds was highly correlated with the airflow from a spirometer, and similar to previously-published studies, we found that the increasing tracheal sounds' amplitude as flow increases follows a power law relationship. Acquired tracheal sounds were used for breath-phase onset detection and their onsets differed by only 52 ± 51 ms (mean ± SD) for Galaxy S4, and 51 ± 48 ms for iPhone 4s, when compared to those detected from the reference signal via the spirometer. Moreover, it was found that accurate respiratory rates (RR) can be obtained from tracheal sounds. The correlation index, bias and limits of agreement were r² = 0.9693, 0.11 (-1.41 to 1.63) breaths-per-minute (bpm) for Galaxy S4, and r² = 0.9672, 0.097 (-1.38 to 1.57) bpm for iPhone 4s, when compared to RR estimated from spirometry. Both smartphone devices performed similarly, as no statistically-significant differences were found.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Reyes et al. (2014) studied this question.

synapsesocial.com/papers/6a160545366ced26f1b56239https://doi.org/10.3390/s140813830
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Multifunction Stethoscope for Telemedicine2006 · 16 citations
  2. 2Pattern Classification (2nd ed.)1999 · 2,516 citations
  3. 3The development of a portable breath sounds analysis system1992 · 10 citations
  4. 4Breath sounds and distribution of pulmonary ventilation1969 · 72 citations
  5. 5Interrater Reliability of Auscultation of Breath Sounds Among Physical Therapists1995 · 90 citations