PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
November 1, 2003British Journal Of Nutrition50 citationsOpen Access

Comparison of commonly used procedures, including the doubly-labelled water technique, in the estimation of total energy expenditure of women with special reference to the significance of body fatness

MLMarie LöfUHUlf HannestadEFElisabet Forsum

Key Points

Key points are not available for this paper at this time.

Abstract

According to the report of the World Health Organization (1985), total energy expenditure (TEE) in human subjects can be calculated as BMR x physical activity level (PAL). However, other reports have pointed out limitations in the suggested procedure related to the % body fat of the subjects. The purpose of the present study was to evaluate the World Health Organization (1985) procedure in thirty-four healthy women with BMI 18-39 kg/m2. BMR and TEE were measured using indirect calorimetry (BMRmeas) and the doubly-labelled water method (TEEref) respectively. When assessed using the doubly-labelled water and skinfold-thickness methods, the women had 34 (SD 8) and 33 (SD 6) % body fat respectively. On the basis of guidelines provided by the World Health Organization (1985), 1.64 was selected to represent the average PAL of the women. Furthermore, PAL was also assessed by means of an accelerometer (PALacc), heart-rate recordings (PAL(HR)) and a questionnaire (PALq). These estimates were: PALacc 1.71 (SD 0.17), PAL(HR) 1.76 (SD 0.24), PALq 1.86 (SD 0.27). These values were lower than TEEref/BMRref, which was 1.98 (SD 0.21). BMR assessed using equations recommended by the World Health Organization (1985) (BMRpredicted) overestimated BMR by 594 (SD 431) kJ/24 h. However, when TEE was calculated as BMRpredicted x PALacc, BMRpredicted x PAL(HR) and BMRpredicted x PALq respectively, average results were in agreement with TEEref. Furthermore, TEE values based on BMRpredicted and PALacc, PAL(HR), PALq as well as on PAL = 1.64, minus TEEref, were significantly correlated with body fatness. When the same PAL value (1.64) was used for all subjects, this correlation was particularly strong. Thus, the World Health Organization (1985) procedure may give TEE results that are biased with respect to the body fatness of subjects.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Löf et al. (2003) studied this question.

synapsesocial.com/papers/6a16cb94b13aec50ea6b8394https://doi.org/10.1079/bjn2003975
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Evaluation of an Automated Equilibration Technique for Deuterium/Hydrogen Isotope Ratio Measurements with Respect to Assessing Total Energy Expenditure by the Doubly Labelled Water Method1997 · 20 citations
  2. 2The doubly-labelled-water ( 2 H 2 18 O) method: principles and practice1988 · 147 citations
  3. 3Techniques for Measuring Body Composition1961 · 1,618 citations
  4. 4New methods for calculating metabolic rate with special reference to protein metabolism1949 · 5,666 citations
  5. 5DOUBLY LABELED WATER VALIDATION OF THE COMPENDIUM OF PHYSICAL ACTIVITIES IN LEAN AND OBESE COLLEGE WOMEN1999 · 20 citations