November 26, 20202 citations

Computerized Diagnosis of the Prolapsed Mitral Valve Using Heart Sound Signal

View Full Paper
MMMahtab MehrabbeikSRSaeid RashidiAFAli Fallah

Key Result

A computerized diagnostic algorithm using phonocardiogram signals and an SVM classifier detected mitral valve prolapse with 95.65% accuracy.

Structured PICO

Can a computerized algorithm using phonocardiogram signals accurately detect mitral valve prolapse?

P
Population
20 patients (15 with prolapsed mitral valve and 5 non-prolapsed)
I
Intervention
Computerized diagnosis algorithm using phonocardiogram (PCG) signals processed with Chebyshev filter, Wavelet Transform, Shannon Energy Envelope, Fractional Fourier Transform, and SVM classifier
O
Outcome
Accuracy of detecting Mitral Valve Prolapsesurrogate

A computerized algorithm processing heart sound signals demonstrated high accuracy in detecting mitral valve prolapse, suggesting potential for automated auscultation-based diagnosis.

Abstract

Cardiovascular diseases (CVDs) are one of the leading causes of death each year. Early diagnosis of CVDs can help to control and prevent the complication of heart diseases. Although auscultation is one of the conventional methods of CVDs diagnosis, it is not accurate enough because of the human hearing restrictions and nonstationary nature of the heart sounds. Because the heart sound or phonocardiogram (PCG) signal contains heart functional information, it can be employed to diagnose various types of CVDs. The goal of this study is to detect Mitral valve Prolapse (PMV) using PCGs. To reach the goal, first, the PCGs were denoised using the Chebyshev filter along with the Wavelet Transform (WT). Then, using the Shannon Energy Envelope (SEE) along with adaptive thresholding, the denoised PCGs were divided into the cardiac cycles. Fractional Fourier Transform (FrFT) was performed to extract the desired features in the time-frequency space. Based on the Mahalanobis distance criterion, the optimal features were selected. The results of the proposed algorithm on the 15 prolapsed and 5 non-prolapsed patients show 95.65% accuracy using the SVM classifier.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Mehrabbeik et al. (2020) studied Mitral valve Prolapse (n=20). Computerized diagnosis using phonocardiogram (PCG) signals was evaluated on Detection accuracy of Mitral valve Prolapse. A computerized diagnostic algorithm using phonocardiogram signals and an SVM classifier detected mitral valve prolapse with 95.65% accuracy.

synapsesocial.com/papers/6a17c72c4f2b3115b012fe88https://doi.org/10.1109/icbme51989.2020.9319464
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Classification of Prolapsed Mitral Valve versus Healthy Heart from Phonocardiograms by Multifractal Analysis2013 · 42 citations
  2. 2Phonocardiography-based mitral valve prolapse detection with using fractional fourier transform2020 · 8 citations
  3. 3A Multi-class SVM Classifier Utilizing Binary Decision Tree2009 · 175 citations
  4. 4Investigating the Performance of Naive- Bayes Classifiers and K- Nearest Neighbor Classifiers2007 · 126 citations
  5. 5Mitral valve prolapse in the general population. 2. Clinical features: The Framingham Study1983 · 183 citations