PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 28, 2026Agricultural Water Management0 citationsOpen Access

Measurement of sap flux density using a single probe through a lumped capacitance method

View Full Paper
FLFuyun LuWYWu YangZZZhi Zhao

Key Points

  • The aim is to establish an accurate single-probe method to measure sap flux density (SFD) in trees.
  • A pulse heating technique was applied using a single probe based on the lumped capacitance method.
  • Model reliability was evaluated on peach, apple, and jujube trees.
  • Field tests compared the new method's SFD outputs to the transient thermal dissipation method.
  • The new method showed predictive accuracy with relative errors less than 12%.
  • SFD measurements closely matched real SFD determined by the weighing method, with RMSEs of 0.353 to 0.712 L dm −2 h −1.
  • A strong correlation was found between field SFD measurements and reference evapotranspiration with Pearson coefficients between 0.58 and 0.85.

Abstract

Accurate measurement of sap flux density (SFD) is crucially important in plant transpiration studies. A novel single-probe method with pulse heating was established to measure SFD, based on both the lumped capacitance method and a proposed logarithmic relationship between the heat exchange coefficient and SFD. Peach, apple, and jujube trees were selected to evaluate the model reliability and accuracy. The results of experiments showed that the proposed method exhibited good predictive accuracy, with relative errors (REs) of less than 12%. For all tree species, SFD measured by the proposed method showed strong agreement with the real SFD determined by the weighing method, with root mean square errors (RMSEs) ranging from 0.353 to 0.712 L dm −2 h −1 . Field tests showed that the daytime outputs from the proposed method closely matched those measured by the transient thermal dissipation method (linear model), with R 2 > 0.95. The slopes of the linear fit for SFD predictions were 0.818, 0.981, and 1.041 for peach, apple, and jujube trees, respectively, with corresponding intercepts of 0.518, 0.338, and 0.647 L dm −2 h −1 . In addition, the field SFD measurements were significantly and linearly correlated with reference evapotranspiration (ETo). The Pearson correlation coefficients between predicted SFDs and ETo were 0.84, 0.58, and 0.85 for peach, apple, and jujube trees, respectively, supporting the rationality of predictions by the proposed method. Similar to existing models, the proposed model still requires species-specific calibration and shows reduced accuracy under near-zero SFD conditions. This study provides an accurate and energy-efficient alternative for sap flow measurement, while reducing wounding effects compared with multi-probe methods.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lu et al. (2026) studied this question.

synapsesocial.com/papers/6a17daf83fad632b0f9d7d2dhttps://doi.org/10.1016/j.agwat.2026.110466
Ask AI
Helpful
Bookmark
Share
View Full Paper