December 23, 2011IEEE Transactions on Instrumentation and Measurement342 citations

A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter

View Full Paper
MRM. Raghu RamKMK. Venu MadhavEKE. Hari Krishna

Key Result

An AS-LMS adaptive filter using an internally generated synthetic noise reference signal effectively reduced motion artifacts in PPG signals without requiring additional hardware.

Structured PICO

P
Population
Photoplethysmographic (PPG) signals corrupted by motion artifacts
I
Intervention
Adaptive step-size least mean squares (AS-LMS) adaptive filter using an internally generated synthetic noise reference signal
O
Outcome
Reduction of motion artifacts in corrupted PPG signalssurrogate

An AS-LMS adaptive filter using an internally generated noise reference signal effectively reduces motion artifacts in PPG signals without requiring additional hardware.

Abstract

The performance of pulse oximeters is highly influenced by motion artifacts (MAs) in photoplethysmographic (PPG) signals. In this paper, we propose a simple and efficient approach based on adaptive step-size least mean squares (AS-LMS) adaptive filter for reducing MA in corrupted PPG signals. The presented method is an extension to our prior work on efficient use of adaptive filters for reduction of MA in PPG signals. The novelty of the method lies in the fact that a synthetic noise reference signal for an adaptive filtering process, representing MA noise, is generated internally from the MA-corrupted PPG signal itself instead of using any additional hardware such as accelerometer or source-detector pair for acquiring noise reference signal. Thus, the generated noise reference signal is then applied to the AS-LMS adaptive filter for artifact removal. While experimental results proved the efficacy of the proposed scheme, the merit of the method is clearly demonstrated using convergence and correlation analysis, thus making it best suitable for present-day pulse oximeters utilizing PPG sensor head with a single pair of source and detector, which does not have any extra hardware meant for capturing noise reference signal. In addition to arterial oxygen saturation estimation, the artifact reduction method facilitated the waveform contour analysis on artifact-reduced PPG, and the conventional parameters were evaluated for assessing the arterial stiffness.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ram et al. (2011) studied Motion artifacts in photoplethysmographic (PPG) signals. AS-LMS adaptive filter with internally generated synthetic noise reference signal was evaluated on Motion artifact reduction evaluated via convergence and correlation analysis. An AS-LMS adaptive filter using an internally generated synthetic noise reference signal effectively reduced motion artifacts in PPG signals without requiring additional hardware.

synapsesocial.com/papers/6a180d7256b3e2ada412e019https://doi.org/10.1109/tim.2011.2175832
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Removal of Motion Artifacts in PPG Signals Based on the CEEMDAN-MPE and VS_LMS Adaptive Filter2024 · 7 citations
  2. 2Adaptive reduction of motion artifact from photoplethysmographic recordings using a variable step-size LMS filter2003 · 105 citations
  3. 3An Adaptive Filter Based Motion Artifact Cancellation Technique Using Multi-Wavelength PPG for Accurate HR Estimation2023 · 17 citations
  4. 4Adaptive Algorithm for Motion Artifacts Removal in Wearable Biomedical Sensors During Physical Exercise2023 · 18 citations
  5. 5Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography2007 · 103 citations