PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 1, 2023ACS Nano42 citations

Ultrafast (∼0.6 s), Robust, and Highly Linear Hydrogen Detection up to 10% Using Fully Suspended Pure Pd Nanowire

View Full Paper
MJMin‐Seung JoKKKi-Hoon KimJLJae‐Shin Lee

Key Points

Key points are not available for this paper at this time.

Abstract

The high explosiveness of hydrogen gas in the air necessitates prompt detection in settings where hydrogen is used. For this reason, hydrogen sensors are required to offer rapid detection and possess superior sensing characteristics in terms of measurement range, linearity, selectivity, lifetime, and environment insensitivity according to the publicized protocol. However, previous approaches have only partially achieved the standardized requirements and have been limited in their capability to develop reliable materials for spatially accessible systems. Here, an electrical hydrogen sensor with an ultrafast response (∼0.6 s) satisfying all demands for hydrogen detection is demonstrated. Tailoring structural engineering based on the reaction kinetics of hydrogen and palladium, an optimized heating architecture that thermally activates fully suspended palladium (Pd) nanowires at a uniform temperature is designed. The developed Pd nanostructure, at a designated temperature distribution, rapidly reacts with hydrogen, enabling a hysteresis-free response from 0.1% to 10% and durable characteristics in mechanical shock and repetitive operation (>10,000 cycles). Moreover, the device selectively detects hydrogen without performance degradation in humid or carbon-based interfering gas circumstances. Finally, to verify spatial accessibility, the wireless hydrogen detection system has been demonstrated, detecting and reporting hydrogen leakage in real-time within just 1 s.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jo et al. (2023) studied this question.

synapsesocial.com/papers/6a188b13cc5c8ef9ac65d9d5https://doi.org/10.1021/acsnano.3c06806
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Wireless and Linear Hydrogen Detection up to 4% with High Sensitivity through Phase-Transition-Inhibited Pd Nanowires2022 · 47 citations
  2. 2The effect of heat treatment in air on CO inhibition of a ∼3μm Pd–Ag (23wt.%) membrane2010 · 50 citations
  3. 3High-temperature MEMS Heater Platforms: Long-term Performance of Metal and Semiconductor Heater Materials2006 · 89 citations
  4. 4Nanosize Effects on Hydrogen Storage in Palladium2008 · 392 citations
  5. 5Hysteresis-Free Nanoplasmonic Pd–Au Alloy Hydrogen Sensors2015 · 209 citations