PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 1, 1996Brain178 citationsOpen Access

Quantitative assessment of MRI lesion load in multiple sclerosis: A comparison of conventional spin-echo with fast fluidattenuated inversion recovery

View Full Paper
MFMassimo FilippiCBCorrado BarattiTYTarek Yousry

Key Points

Key points are not available for this paper at this time.

Abstract

In this study, we compared a fast fluid-attenuated inversion recovery (fast-FLAIR) sequence to conventional spin-echo (CSE) in the evaluation of brain MRI lesion loads of seven patients with clinically definite multiple sclerosis. Interleaved CSE (3000/20, 5 mm contiguous axial slices) and fast-FLAIR (9000/150/2200, 5 mm contiguous axial slices) sequences were performed on a 1.0 T machine. Lesions were counted consensually by two observers and then segmented independently by two other observers using a local thresholding technique, with subsequent manual editing in the case of poorly defined lesions. Four hundred and two lesions were detected in at least one of the two sequences: 128 were seen only on fast-FLAIR, 17 only on CSE. Forty-one lesions were larger on fast-FLAIR, while no lesion was considered larger on CSE. The numbers of periventricular (P = 0.05), cortical/subcortical (P = 0.02) and discrete (P = 0.05) lesions detected using fast-FLAIR were higher than those detected using CSE. The median lesion load was 7185 mm3 on CSE and 8418 mm3 on the fast-FLAIR, the average being 18% (range = 11.6-29%) higher on the fast-FLAIR images. Lesion contrast ratio was higher for lesions on the fast-FLAIR than on the CSE sequence (P < 0.0001). The percentages of poorly defined lesions which needed manual editing after the local thresholding technique was applied and the total time needed for the measurements were lower (P < 0.001) when fast-FLAIR images were used compared with CSE. This resulted in a reduced inter-rater coefficient of variation in measuring lesion volumes. Our data indicate that fast-FLAIR sequences are more sensitive than CSE in detecting multiple sclerosis lesion burden and that fast-FLAIR is a promising technique for natural history studies and clinical trials in multiple sclerosis.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Filippi et al. (1996) studied this question.

synapsesocial.com/papers/6a19ea1a443d3ecd7cdf2809https://doi.org/10.1093/brain/119.4.1349
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Resolution‐dependent estimates of lesion volumes in magnetic resonance imaging studies of the brain in multiple sclerosis1995 · 74 citations
  2. 2Correlations between changes in disability and T 2 ‐weighted brain MRI activity in multiple sclerosis1995 · 298 citations
  3. 3A comparison of the pathology of primary and secondary progressive multiple sclerosis1994 · 295 citations
  4. 4New diagnostic criteria for multiple sclerosis: Guidelines for research protocols1983 · 7,418 citations
  5. 5Quantitative MRI studies for assessment of multiple sclerosis1992 · 43 citations