Clinical Evaluation of Stretchable and Wearable Inkjet-Printed Strain Gauge Sensor for Respiratory Rate Monitoring at Different Body Postures

AAAla‘aldeen Al-HalhouliLALoiy Al‐GhussainSBSaleem El Bouri

Key Points

Key points are not available for this paper at this time.

Abstract

Respiratory rate (RR) is a vital sign with continuous, convenient, and accurate measurement which is difficult and still under investigation. The present study investigates and evaluates a stretchable and wearable inkjet-printed strain gauge sensor (IJP) to estimate the RR continuously by detecting the respiratory volume change in the chest area. As the volume change could cause different strain changes at different body postures, this study aims to investigate the accuracy of the IJP RR sensor at selected postures. The evaluation was performed twice on 15 healthy male subjects (mean ± SD of age: 24 ± 1.22 years). The RR was simultaneously measured in breaths per minute (BPM) by the IJP RR sensor and a reference RR sensor (e-Health nasal thermal sensor) at each of the five body postures namely standing, sitting at 90°, Flower’s position at 45°, supine, and right lateral recumbent. There was no significant difference in measured RR between IJP and reference sensors, between two trials, or between different body postures (all p > 0.05). Body posture did not have any significant effect on the difference of RR measurements between IJP and the reference sensors (difference <0.01 BPM for each measurement in both trials). The IJP sensor could accurately measure the RR at different body postures, which makes it a promising, simple, and user-friendly option for clinical and daily uses.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Al-Halhouli et al. (2020) studied this question.

synapsesocial.com/papers/6a1b6a1f03445f1b1e0c3fdchttps://doi.org/10.3390/app10020480
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Effect of posture on respiratory function and drive in preterm infants prior to discharge2003 · 37 citations
  2. 2Testing Properties of E-health System Based on Arduino2015 · 19 citations
  3. 3Respiratory rate 1: why measurement and recording are crucial.2018 · 25 citations
  4. 4Posture-Specific Breathing Detection2018 · 8 citations
  5. 5Clinical evaluation of a novel respiratory rate monitor2015 · 50 citations