PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 10, 2013AJP Heart and Circulatory Physiology33 citations

Aspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris

View Full Paper
PKPetra KleinbongardTBTheodor BaarsSMStefan Möhlenkamp

Structured PICO

Does coronary aspirate from stented native right coronary arteries differ in particulate debris and vasoconstrictor release compared to saphenous vein grafts?

P
Population
36 symptomatic male patients with stable angina pectoris and a flow-limiting stenosis in their native right coronary arteries (nRCA, n=18) or saphenous vein grafts on right coronary arteries (SVG-RCA, n=18).
I
Intervention
Stent implantation in native right coronary arteries (nRCA) under protection with a distal occlusion/aspiration device
C
Comparator
Stent implantation in saphenous vein grafts on right coronary arteries (SVG-RCA) under protection with a distal occlusion/aspiration device
O
Outcome
Amount of particulate debris, release of soluble mediators (catecholamines, endothelin, serotonin, thromboxane B2, TNF-α), and vasoconstrictor response of rat mesenteric arteries to aspirate plasmasurrogate

Stenting of native right coronary arteries releases less particulate debris but more endothelin, leading to stronger vasoconstriction compared to saphenous vein grafts, highlighting different mechanisms of potential microvascular obstruction.

Abstract

Stent implantation into atherosclerotic coronary arteries releases particulate debris and soluble substances that contribute to impaired microvascular perfusion. Here we addressed the potential for microvascular obstruction in patients with stenotic native right coronary arteries (nRCA) compared with saphenous vein grafts on right coronary arteries (SVG-RCA). We enrolled symptomatic, male patients with stable angina pectoris and a flow-limiting stenosis in their nRCA or SVG-RCA (n = 18/18). Plaque volume and composition were analyzed using intravascular ultrasound before stent implantation. Coronary aspirate was retrieved during stent implantation under protection with a distal occlusion/aspiration device and divided into particulate debris and plasma. The release of catecholamines, endothelin, serotonin, thromboxane B2, and tumor necrosis factor-α was measured. The response of rat mesenteric arteries with intact (+E) and denuded (-E) endothelium to aspirate plasma (without and with selective endothelin receptor blockade) was normalized to that by potassium chloride (KClmax = 100%). Plaque volume and composition were not different between nRCA and SVG-RCA. There was less particulate debris (65 ± 8 vs. 146 ± 23 mg; P < 0.05) and more endothelin release (5.8 ± 0.8 vs. 1.3 ± 0.7 pg/ml; P < 0.05) in nRCA than in SVG-RCA, whereas the release of the other mediators was not different. Aspirate from nRCA induced stronger vasoconstriction than that from SVG-RCA nRCA, 78 ± 6% (+E)/84 ± 5% (-E); SVG-RCA, 59 ± 6% (+E)/68 ± 3% (-E); P < 0.05 nRCA vs. SVG-RCA, which was attenuated by a nonspecific endothelin and a specific endothelin receptor A antagonist. Thus coronary aspirate from stented nRCA is characterized by less debris but more endothelin and stronger vasoconstrictor response than that from SVG-RCA.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kleinbongard et al. (2013) studied this question.

synapsesocial.com/papers/6a1b82196a7f159d19e8d43ahttps://doi.org/10.1152/ajpheart.00358.2013
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Active endothelin is an important vasoconstrictor in acute coronary thrombi2007 · 37 citations
  2. 2Cyclooxygenases-1 and −2 of Endothelial Cells Utilize Exogenous or Endogenous Arachidonic Acid for Transcellular Production of Thromboxane1996 · 128 citations
  3. 3The Thrombolysis in Myocardial Infarction (TIMI) Trial1985 · 3,190 citations
  4. 4Endothelin-1 and acute myocardial infarction: a no-reflow mediator after successful percutaneous myocardial revascularization2006 · 111 citations
  5. 5Coronary no-reflow is caused by shedding of active tissue factor from dissected atherosclerotic plaque2002 · 133 citations