Smartwatch-derived heart rate variability: a head-to-head comparison with the gold standard in cardiovascular disease

View Full Paper
FTFabian TheurlMSMichael SchreinlechnerNSNikolay Sappler

Structured PICO

Does smartwatch-derived photoplethysmography accurately measure heart rate variability compared to high-resolution ECG in patients with cardiovascular disease?

P
Population
263 subjects, comprising 104 survivors of acute ST-elevation myocardial infarction, 129 patients after an ischaemic stroke, and 30 controls.
I
Intervention
Smartwatch (Garmin vivoactive 4)-derived photoplethysmographic (PPG) signal recorded for 30 min under standardized conditions.
C
Comparator
Simultaneous recording with gold-standard high-resolution (1000 Hz) electrocardiogram (ECG).
O
Outcome
Concordance between smartwatch-derived and ECG-based HRV markers measured by Lin's concordance correlation coefficient (ρc).surrogate

Smartwatch-derived HRV provides excellent accuracy for global and lower-frequency markers compared to ECG, but is less accurate for short-term variability markers in cardiovascular patients.

Abstract

Abstract Aims We aimed to investigate the concordance between heart rate variability (HRV) derived from the photoplethysmographic (PPG) signal of a commercially available smartwatch compared with the gold-standard high-resolution electrocardiogram (ECG)-derived HRV in patients with cardiovascular disease. Methods and results We prospectively enrolled 104 survivors of acute ST-elevation myocardial infarction, 129 patients after an ischaemic stroke, and 30 controls. All subjects underwent simultaneous recording of a smartwatch (Garmin vivoactive 4; Garmin Ltd, Olathe, KS, USA)-derived PPG signal and a high-resolution (1000 Hz) ECG for 30 min under standardized conditions. HRV measures in time and frequency domain, non-linear measures, as well as deceleration capacity (DC) were calculated according to previously published technologies from both signals. Lin’s concordance correlation coefficient (ρc) between smartwatch-derived and ECG-based HRV markers was used as a measure of diagnostic accuracy. A very high concordance within the whole study cohort was observed for the mean heart rate (ρc = 0.9998), standard deviation of the averages of normal-to-normal (NN) intervals in all 5min segments (SDANN; ρc = 0.9617), and very low frequency power (VLF power; ρc = 0.9613). In contrast, detrended fluctuation analysis (DF-α1; ρc = 0.5919) and the square mean root of the sum of squares of adjacent NN-interval differences (rMSSD; ρc = 0.6617) showed only moderate concordance. Conclusion Smartwatch-derived HRV provides a practical alternative with excellent accuracy compared with ECG-based HRV for global markers and those characterizing lower frequency components. However, caution is warranted with HRV markers that predominantly assess short-term variability.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Theurl et al. (2023) studied this question.

synapsesocial.com/papers/6a1b8a788df86b99f942dc71https://doi.org/10.1093/ehjdh/ztad022
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Abnormalities in Beat-to-Beat Dynamics of Heart Rate Before the Spontaneous Onset of Life-Threatening Ventricular Tachyarrhythmias in Patients With Prior Myocardial Infarction1996 · 279 citations
  2. 2Neural Activity and Ventricular Fibrillation1976 · 770 citations
  3. 3Validation of the Apple Watch for Heart Rate Variability Measurements during Relax and Mental Stress in Healthy Subjects2018 · 235 citations
  4. 4Advances in heart rate variability signal analysis: joint position statement by the e-Cardiology ESC Working Group and the European Heart Rhythm Association co-endorsed by the Asia Pacific Heart Rhythm Society2015 · 737 citations
  5. 5Continuous Autonomic Assessment in Patients With Symptomatic Heart Failure2004 · 311 citations