PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 1, 2008Journal of Arrhythmia15 citationsOpen Access

Current status of implantable defibrillator devices in patients with left ventricular dysfunction — The first report from the online registry database

View Full Paper
ASAkihiko ShimizuTNTakashi NittaTKTakashi Kurita

Structured PICO

P
Population
1,584 patients with left ventricular dysfunction (LVEF ≦ 40%) who had an implantable cardioverter-defibrillator (ICD) or cardiac-resynchronization therapy with implantable defibrillator (CRT-D), from the Japanese Cardiac Device Treatment Registry database.
I
Intervention
Implantable cardioverter-defibrillator (ICD) or cardiac-resynchronization therapy with implantable defibrillator (CRT-D)
O
Outcome
Difference in clinical characteristics between primary and secondary prevention groups and transition of indications for device implantation over time

In Japan, the use of ICD/CRT-D devices for primary prevention is increasing but remains significantly lower in patients with ischemic heart disease compared to those with dilated cardiomyopathy.

Abstract

Background: The current status of the efficacy of implantable cardioverter‐defibrillator (ICD. and cardiac‐resynchronization therapy with implantable defibrillator (CRT‐D. in patients with left ventricular dysfunction needs to be clarified. Methods and Results: From the Japanese Cardiac Device Treatment Registry database, a total of 1,584 patients who had an LVEF ≦ 40% and had an ICD or CRT‐D were selected as subjects in this study. The difference in the clinical characteristics between the primary and secondary prevention groups and the transition of the indications for device implantation over time were examined. Primary prevention gradually increased up to about 50% in all patients. The implantations of ICD/CRT‐D for primary prevention in ischemic hear disease was significantly lower than that in dilated cardiomyopathy (33% vs 51%; p < 0.0001). The number of implantations for CRT‐D for primary prevention increased dramatically over a one‐year period. Conclusions: In Japan, the implantable defibrillator devices for primary prevention was significantly lower in ischemic heart disease compared with dilated cardiomyopathy. Further, an extension of the indications for ICD/CRT‐D implantations has recently been occurring, especially with CRT‐D devices for primary prevention.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Shimizu et al. (2008) studied this question.