PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 12, 2007EP Europace43 citations

Upgrading to biventricular pacing/defibrillation systems in right ventricular paced congestive heart failure patients: prospective assessment of procedural parameters and response rate

View Full Paper
GDGábor Zoltán DurayCICarsten W. IsraelDPD. Pajitnev

Structured PICO

Does upgrading to CRT from a right ventricular system have comparable implantation success and clinical response to de novo CRT implantation in heart failure patients?

P
Population
79 consecutive patients scheduled for cardiac resynchronization therapy (CRT) (mean age 64 +/- 11 years, 63 male, 38 ischaemic, 41 non-ischaemic cardiomyopathy)
I
Intervention
Upgrade procedure to biventricular pacing/defibrillation (CRT) from previously implanted right ventricular system
C
Comparator
De novo CRT implantation
O
Outcome
Implantation success, procedural parameters (procedure duration, fluoroscopy time, fluoroscopy dose), and clinical response

Upgrading existing right ventricular systems to CRT has comparable procedural success and clinical response rates to de novo CRT implantations.

Abstract

AIMS: Cardiac resynchronization therapy (CRT) is indicated in patients with heart failure and bundle branch block. It is less clear whether this includes patients with pre-existing right ventricular pacemaker/defibrillator systems, particularly with respect to implantation success and clinical benefit. METHODS AND RESULTS: In consecutive patients scheduled for CRT, we prospectively compared implantation success, procedural parameters, and clinical response in 'de novo' vs. upgrade procedures of previously implanted right ventricular systems. CRT implantation was attempted in 79 consecutive patients (64 +/- 11 years, 63 male, 38 ischaemic, 41 non-ischaemic cardiomyopathy). De novo implantation was performed in 61 patients, upgrade procedures in 18 patients. Implant success (92 vs. 94%, P = 1.00), procedure duration (153 +/- 43 vs. 164 +/- 65 min, P = 0.51), fluoroscopy time (25 +/- 18 vs. 32 +/- 22 min, P = 0.18) or dose (40 +/- 31 vs. 52 +/- 49 Gy/cm(2), P = 0.35), and response rate (66 vs. 59%, P = 0.5) were comparable for both groups. CONCLUSION: Procedural aspects, implantation success, and clinical response to CRT were comparable for patients undergoing de-novo vs. upgrade procedures. Accordingly, patient selection for upgrading should be the same as for new CRT implantation.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Duray et al. (2007) studied this question.

synapsesocial.com/papers/6a1bc42f4ebd09f3dfa8f81fhttps://doi.org/10.1093/europace/eum259
Ask AI
Helpful
Bookmark
Share
View Full Paper