September 1, 1997Investigative Radiology36 citations

Assessment of Regional Left Ventricular Wall Parameters from Short Axis Magnetic Resonance Imaging using a Three-Dimensional Extension to the Improved Centerline Method

View Full Paper
VBV.G.M. BullerLeiden UniversityRGRob J. van der GeestCardiac ImagingMKMARTIN D. KOOLLeiden University

Structured PICO

Does a 3-D wall thickness calculation algorithm improve the accuracy of left ventricular wall thickness measurements compared to conventional 2-D methods in healthy individuals and phantoms?

P
Population
Left ventricular-shaped software phantoms and MR imaging data from 20 healthy individuals
I
Intervention
Three-dimensional (3-D) wall thickness calculation algorithm based on the 2-D improved centerline method
C
Comparator
Conventional two-dimensional (2-D) methods for wall thickness measurement
O
Outcome
Accuracy of wall thickness measurements (overestimation error)surrogate

A newly developed 3-D approach for measuring cardiac wall thickness from short-axis MR studies provides higher accuracy than the conventional 2-D approach by reducing overestimation errors.

Abstract

RATIONALE AND OBJECTIVES: Short-axis magnetic resonance images of the cardiac left ventricle, acquired in multiple slices and phases, may be used for the quantitative assessment of regional wall parameters. Conventional two-dimensional (2-D) methods for wall thickness measurement rely on information within one imaging plane, which may result in overestimation of the true thickness depending on the local direction of myocardial wall with respect to the imaging plane. METHODS: To perform wall thickness measurements truly perpendicular to the myocardial wall, a three-dimensional (3-D) wall thickness calculation algorithm has been developed based on the 2-D improved centerline method. An evaluation was performed on left ventricular-shaped software phantoms, and on the magnetic resonance (MR) imaging data obtained from 20 healthy individuals. RESULTS: The 3-D method applied to software phantoms with an angulation within 20 degrees of the true short-axis orientation demonstrated only a 1.6% overestimation of wall thickness at the mid to low slices, and a 10.6% error at the apex (2-D measurements: 8.1% and 28.6%, respectively). Three-dimensionally calculated wall thickness in the healthy individuals was systematically and significantly smaller than corresponding 2-D wall thickness (by 11.2%, 8.7%, and 2.6% at the apical, low, and mid slices, respectively). CONCLUSIONS: Cardiac wall thickness measurements from short-axis MR studies can be obtained with a higher accuracy by the newly developed 3-D approach than with the conventional 2-D approach.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Buller et al. (1997) studied this question.