PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 2019Procedia Computer Science95 citationsOpen Access

A Real-time PPG Quality Assessment Approach for Healthcare Internet-of-Things

View Full Paper
ENEmad Kasaeyan NaeiniIAIman AzimiARAmir M. Rahmani

Structured PICO

I
Intervention
Convolutional Neural Networks (CNN) approach for PPG quality assessment
O
Outcome
Accuracy of the proposed approach

A novel CNN-based approach for assessing PPG signal quality in IoT health monitoring systems may help discard unreliable data and prevent false alarms.

Abstract

Photoplethysmography (PPG) as a non-invasive and low-cost technique plays a significant role in wearable Internet-of-Things based health monitoring systems, enabling continuous health and well-being data collection. As PPG monitoring is relatively simple, non-invasive, and convenient, it is widely used in a variety of wearable devices (e.g., smart bands, smart rings, smartphones) to acquire different vital signs such as heart rate and pulse rate variability. However, the accuracy of such vital signs highly depends on the quality of the signal and the presence of artifacts generated by other resources such as motion. This unreliable performance is unacceptable in health monitoring systems. To tackle this issue, different studies have proposed motion artifacts reduction and signal quality assessment methods. However, they merely focus on improvements in the results and signal quality. Therefore, they are unable to alleviate erroneous decision making due to invalid vital signs extracted from the unreliable PPG signals. In this paper, we propose a novel PPG quality assessment approach for IoT-based health monitoring systems, by which the reliability of the vital signs extracted from PPG quality is determined. Therefore, unreliable data can be discarded to prevent inaccurate decision making and false alarms. Exploiting a Convolutional Neural Networks (CNN) approach, a hypothesis function is created by comparing heart rate in the PPG with corresponding heart rate values extracted from ECG signal. We implement a proof-of-concept IoT-based system to evaluate the accuracy of the proposed approach.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Naeini et al. (2019) studied this question.

synapsesocial.com/papers/6a1bd1db0a1f7575939cfddbhttps://doi.org/10.1016/j.procs.2019.04.074
Ask AI
Helpful
Bookmark
Share
View Full Paper