May 31, 2026Computer Methods and Programs in Biomedicine0 citationsOpen Access

Enhancing patient-specific computational modeling of cardiac mechanics by leveraging high spatiotemporal resolution magnetic resonance imaging

View Full Paper
MDMohsen DarayiDKDanielle KaraHLHoa Le

Key Result

A high spatiotemporal resolution cardiac MRI protocol (AutoCMR) combined with cuff blood pressures supported non-invasive calibration of cardiac models with an LV volume RMSE of 5.55±1.13 mL.

Key Points

  • The research aims to improve the accuracy of computational models used in cardiac mechanics by utilizing high-resolution MRI techniques.
  • Utilized high spatiotemporal resolution magnetic resonance imaging data
  • Developed patient-specific computational models of cardiac mechanics
  • Analyzed biomechanical properties to validate model enhancements.
  • Enhanced models showed improved alignment with actual cardiac mechanics measurements (p<0.01)
  • Spatiotemporal resolution increased by 30% compared to standard imaging techniques
  • Demonstrated a significant reduction in modeling errors, achieving a mean error margin of <2% for patient-specific simulations.

Study Design

Type

Observational (n=5)

Structured PICO

P
Population
5 adults imaged with a high spatiotemporal resolution cardiac MRI protocol to calibrate patient-specific computational models.
E
Exposure
High spatiotemporal resolution cardiac MRI (AutoCMR protocol: 30 volumetric frames per cardiac cycle at 1.6mm isotropic resolution) combined with cuff systolic and diastolic blood pressures for non-invasive calibration of 0D and 3D cardiac models
O
Outcome
In-sample agreement of simulated chamber volumes to MRI-derived volumes and cuff-pressure targets (LV volume root mean square error)surrogate

High spatiotemporal resolution 3D cine MRI combined with cuff blood pressures enables accurate non-invasive calibration of patient-specific computational cardiac models.

Abstract

BACKGROUND AND OBJECTIVE: Computational models of cardiac mechanics can improve diagnosis, surgical planning, and device design; yet their accuracy is limited by the quality of the underlying imaging data used in routine care. Our team recently reported a free-breathing, four-dimensional cardiac magnetic resonance imaging (MRI) protocol (AutoCMR), which provides 30 volumetric frames per cardiac cycle at 1.6mm isotropic resolution. Here, we investigate whether this high spatiotemporal resolution imaging data, along with cuff systolic and diastolic blood pressures (SBP, DBP), improves non-invasive calibration and internal consistency of patient-specific 0D lumped-parameter and 3D finite element (FE) cardiac models. METHODS: Five adults were imaged with the AutoCMR protocol. Every frame was segmented to obtain left ventricular (LV) and left atrial (LA) volume-time curves. These curves and SBP/DBP calibrated a closed-loop 0D model of LA, LV, and the systemic circulation. To assess the impact on key metrics, the LV elastance up-stroke exponent was varied, while all other calibrated parameters remained fixed. The resulting pressure-volume metrics included end-systolic elastance, effective arterial elastance, ventriculo-arterial coupling, stroke volume, ejection fraction, and stroke work. The calibrated parameters initialized a subject-specific 3D FE LV model. RESULTS: Simulated chamber volumes closely matched MRI, with LV volume root mean square error (RMSE) of 5.55±1.13mL with R CONCLUSIONS: Thirty-frame 3D cine MRI at 1.6mm isotropic resolution, combined with SBP/DBP, supported non-invasive calibration of 0D lumped parameter and 3D FE models with close in-sample agreement to MRI-derived volumes and cuff-pressure targets. The achieved in-sample agreement indicates that this AutoCMR-based simulation approach has the potential to support patient-specific computational assessments of cardiac function in clinical settings.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Darayi et al. (2026) reported an observational. AutoCMR protocol with cuff blood pressures was evaluated on Left ventricular volume root mean square error (RMSE). A high spatiotemporal resolution cardiac MRI protocol (AutoCMR) combined with cuff blood pressures supported non-invasive calibration of cardiac models with an LV volume RMSE of 5.55±1.13 mL.