PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 1, 2019EuroIntervention53 citations

Long-term results and durability of the CoreValve transcatheter aortic bioprosthesis: outcomes beyond five years

View Full Paper
RPRoberta Antonazzo PanicoCGCristina GianniniMCMarco De Carlo

Key Result

TAVI with the CoreValve device demonstrated good durability at 7-year follow-up, with cumulative incidences of structural valve deterioration of 3.6% and bioprosthetic valve failure of 2.5%.

Study Design

Type

Cohort (n=278)

Multicenter

No

Structured PICO

Does TAVI with the third-generation CoreValve device provide durable long-term outcomes in high-risk patients?

P
Population
278 consecutive high-risk patients who underwent transcatheter aortic valve implantation (TAVI), mean age 82±6 years, mean STS score 6.4±5.0%.
I
Intervention
Transcatheter aortic valve implantation (TAVI) with the third-generation CoreValve device.
O
Outcome
Structural valve deterioration and bioprosthetic valve failure according to the 2017 EAPCI/ESC/EACTS definition of valve durability.hard clinical

The third-generation CoreValve bioprosthesis demonstrates good long-term durability with low rates of structural valve deterioration and bioprosthetic valve failure beyond five years.

Abstract

AIMS: The aim of this study was to determine the long-term outcomes of high-risk patients who underwent transcatheter aortic valve implantation (TAVI) with the third-generation CoreValve device, according to the 2017 EAPCI/ESC/EACTS definition of valve durability. METHODS AND RESULTS: Between 2007 and 2013, 278 consecutive patients were enrolled in our prospective single-centre CoreValve registry (mean age 82±6 years, mean STS score 6.4±5.0%). The median follow-up of survivors was 6.8 years. The Cox proportional hazards model was used to identify independent predictors of HF rehospitalisation and all-cause mortality. Predictors of HF rehospitalisation were LVEF, MR and PVL at the last echocardiographic follow-up. The majority of patients were in NYHA Class I or II and showed mild/trivial paravalvular leak throughout follow-up. Mean pressure gradients remained stable over time. The overall crude cumulative incidences of structural valve deterioration and bioprosthetic valve failure were 3.6% and 2.5%, respectively. CONCLUSIONS: Although overall mortality was high in this elderly patient cohort, the CoreValve bioprosthesis showed good durability at seven-year follow-up.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Panico et al. (2019) conducted a cohort in High-risk patients undergoing TAVI (n=278). Transcatheter aortic valve implantation (TAVI) with the third-generation CoreValve device was evaluated on Structural valve deterioration and bioprosthetic valve failure. TAVI with the CoreValve device demonstrated good durability at 7-year follow-up, with cumulative incidences of structural valve deterioration of 3.6% and bioprosthetic valve failure of 2.5%.

synapsesocial.com/papers/6a1bfcf601af05bf0da9086chttps://doi.org/10.4244/eij-d-18-00779
Ask AI
Helpful
Bookmark
Share
View Full Paper