PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
November 22, 2018Clinical Oral Implants Research60 citationsOpen Access

Titanium dental implants with different collar design and surface modifications: A systematic review on survival rates and marginal bone levels

View Full Paper
AMAna MessiasPNPedro NicolauFGFernando Guerra

Key Points

Key points are not available for this paper at this time.

Abstract

AIM: The aim of this study was to compare clinical and radiographic outcomes of dental implants with different neck characteristics. METHODS: A protocol-oriented search aimed at the question: "In patients subjected to tooth replacement with screw-type dental implants does the modification of the implant neck macro- or microgeometry contribute to the improvement of survival rates and maintenance of the peri-implant marginal bone levels?" Primary outcomes were survival and marginal bone level (MBL) changes evaluated on randomized controlled trials with >10 participants and follow-up >1 year. Risk of bias was evaluated using the Cochrane Collaboration's tool. The review follows the PRISMA statement. RESULTS: Forty-three studies compared: (a) One- versus two-piece implants (N = 7); (b) Two-piece implants with different neck characteristics (machined and rough collars, microthreads, LASER microtexturing) (N = 21); (c) Two-piece implants with macrogeometry modifications (tapering, back-tapering, and scalloping) (N = 6). One- and two-piece implants showed similar survival (RR = 0.45, 95% CI: 0.12, 1.66, p = 0.23) and MBL changes (WMD = 0.09 mm, 95% CI: -0.27, 0.45, p = 0.64) at 1-year post-loading. Machined collar implants have higher risk of early failure than rough collar implants (RR = 3.96, 95% CI: 1.12, 13.93, p = 0.03) and 0.43 mm higher bone resorption (95% CI: 0.0, 0.86, p = 0.05). Microthreads (WMD = 0.07 mm, 95% CI: -0.01, 0.15, p = 0.10) and LASER microtexturing (WMD = 0.15 mm, 95% CI: -0.35, 0.65, p = 0.56) do not reduce bone resorption. Scalloped implants have 1.26 mm higher resorption (95% CI: 0.72, 2.00, p < 0.001). CONCLUSIONS: One- and two-piece implants have similar survival and MBL changes. Rough collar implants have lower MBL changes than machined collar implants. Additional modifications to rough collars are irrelevant.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Messias et al. (2018) studied this question.

synapsesocial.com/papers/6a1bfd0efc87fd06169cf896https://doi.org/10.1111/clr.13389
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Implant neck configurations for preservation of marginal bone level: a systematic review.2011 · 75 citations
  2. 2Evaluation of Optimal Taper of Immediately Loaded Wide-Diameter Implants: A Finite Element Analysis2011 · 25 citations
  3. 3Early loading of splinted implants supporting a two‐unit fixed partial denture in the posterior maxilla: 13‐month results from a randomized controlled clinical trial of two different implant systems2015 · 13 citations
  4. 4A Double-Blind Randomized Trial Comparing Implants with Laser-Microtextured and Machined Collar Surfaces: Microbiologic and Clinical Results2016 · 16 citations
  5. 5A randomized controlled clinical trial to assess crestal bone remodeling of four different implant designs2018 · 24 citations