Interobserver agreement for neonatal seizure detection using multichannel EEG

View Full Paper
NSNathan J. StevensonRCRobert R. ClancySVSampsa Vanhatalo

Key Points

  • This study aims to assess how consistently experts agree on detecting seizures in neonates using multichannel EEG recordings.
  • Prospective cohort study of full-term neonates at risk of acute encephalopathy.
  • EEG recordings independently reviewed by three international experts for seizure detection.
  • Interobserver agreement assessed using Fleiss' kappa and percentage agreement over seizure events and duration.
  • Kappa of 0.827 (95% CI: 0.769-0.865) indicating high interobserver agreement on seizure detection.
  • Median agreement of 83.0% for seizures and 99.7% for nonseizures among observers.
  • Disagreements were more common for seizures lasting less than 30 seconds.

Abstract

OBJECTIVE: To determine the interobserver agreement (IOA) of neonatal seizure detection using the gold standard of conventional, multichannel EEG. METHODS: A cohort of full-term neonates at risk of acute encephalopathy was included in this prospective study. The EEG recordings of these neonates were independently reviewed for seizures by three international experts. The IOA was estimated using statistical measures including Fleiss' kappa and percentage agreement assessed over seizure events (event basis) and seizure duration (temporal basis). RESULTS: A total of 4066 h of EEG recordings from 70 neonates were reviewed with an average of 2555 seizures detected. The IOA was high with temporal assessment resulting in a kappa of 0.827 (95% CI: 0.769-0.865; n = 70). The median agreement was 83.0% (interquartile range IQR: 76.6-89.5%; n = 33) for seizure and 99.7% (IQR: 98.9-99.8%; n = 70) for nonseizure EEG. Analysis of events showed a median agreement of 83.0% (IQR: 72.9-86.6%; n = 33) for seizures with 0.018 disagreements per hour (IQR: 0.000-0.090 per hour; n = 70). Observers were more likely to disagree when a seizure was less than 30 sec. Overall, 33 neonates were diagnosed with seizures and 28 neonates were not, by all three observers. Of the remaining nine neonates with contradictory EEG detections, seven presented with low total seizure burden. INTERPRETATION: The IOA is high among experts for the detection of neonatal seizures using conventional, multichannel EEG. Agreement is reduced when seizures are rare or have short duration. These findings support EEG-based decision making in the neonatal intensive care unit, inform EEG interpretation guidelines, and provide benchmarks for seizure detection algorithms.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Stevenson et al. (2015) studied this question.

synapsesocial.com/papers/6a1c03480a1f7575939d5ca9https://doi.org/10.1002/acn3.249
Ask AI
Helpful
Bookmark
Share
View Full Paper