Amplitude-Integrated EEG Is Useful in Predicting Neurodevelopmental Outcome in Full-Term Infants With Hypoxic-Ischemic Encephalopathy: A Meta-Analysis

View Full Paper
RSR. Edwin SpitzmillerTPTonya PhillipsJMJareen Meinzen‐Derr

Key Points

  • Assess the effectiveness of amplitude-integrated EEG as a predictor of neurodevelopmental outcomes in full-term infants with hypoxic ischemic encephalopathy.
  • Perform a meta-analysis of literature on amplitude-integrated EEG and outcomes in infants with hypoxic ischemic encephalopathy.
  • Include 8 eligible studies in the primary analysis.
  • Sensitivity of amplitude-integrated EEG for predicting poor outcomes was 91% (95% CI 87-95).
  • Negative likelihood ratio for poor outcome prediction was 0.09 (95% CI 0.06-0.15).
  • Amplitude-integrated EEG is recommended as a bedside tool for outcome prediction in affected infants.

Abstract

Hypoxic ischemic encephalopathy is a common cause of neurological complications resulting in chronic handicapping conditions, such as cerebral palsy. Amplitude-integrated electroencephalography (EEG) has been used in many European countries for more than a decade in the evaluation of infants with hypoxic ischemic encephalopathy but has not been widely used in the United States. The objective of this study was to evaluate the evidence supporting use of amplitude-integrated EEG as a quantitative predictor of neurodevelopmental outcome in full-term infants with hypoxic ischemic encephalopathy. To assess efficacy, the authors performed a meta-analysis of the literature evaluating the use of the amplitude-integrated EEG or cerebral function monitor in full-term infants with hypoxic ischemic encephalopathy and their neurodevelopmental outcome. A total of 8 studies were eligible for the primary meta-analysis. There was an overall sensitivity of 91% (95% CI 87-95) and a negative likelihood ratio of 0.09 (95% CI .06-.15) for amplitude-integrated EEG tracings to accurately predict poor outcome. Amplitude-integrated EEG is a valuable bedside tool for predicting long-term neurodevelopmental outcome in term infants with hypoxic ischemic encephalopathy. This information is useful in structuring communication and care plans for physicians and parents. Early assessment techniques such as amplitude-integrated EEG provide objective means for determining inclusion in clinical studies evaluating therapies for hypoxic ischemic encephalopathy and for predicting which patients are most likely to respond to treatment.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Spitzmiller et al. (2007) studied this question.

synapsesocial.com/papers/6a1c0a711567d2fc4d5f7c14https://doi.org/10.1177/0883073807306258
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Prognostic Significance of Amplitude-Integrated EEG during the First 72 Hours after Birth in Severely Asphyxiated Neonates2004 · 180 citations
  2. 2Amplitude-Integrated Electroencephalography Coupled With an Early Neurologic Examination Enhances Prediction of Term Infants at Risk for Persistent Encephalopathy2003 · 250 citations
  3. 3Perinatal complication: hypoxic-ischemic encephalopathy.2001 · 5 citations
  4. 4HYPOXIC-ISCHEMIC ENCEPHALOPATHY2000 · 530 citations
  5. 5[The importance of using the cerebral function monitor (CFM) in the neurological prognosis of neonates in intensive care].1998 · 3 citations