PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 1, 1998Journal of Biomechanical Engineering123 citationsOpen Access

A Model for Geometric and Mechanical Adaptation of Arteries to Sustained Hypertension

View Full Paper
ARAlexander RachevNSNikolaos StergiopulosJMJ.‐J. Meister

Structured PICO

P
Population
Mathematical model of an arterial wall (thick-walled tube made of nonlinear elastic incompressible material)
I
Intervention
Simulated sustained hypertension (step increase in blood pressure)
C
Comparator
Normotensive conditions
O
Outcome
Evolution of geometric dimensions and mechanical properties of the arterial wall

A phenomenological model of arterial wall remodeling under hypertension predicts that geometric adaptation normalizes stress distribution while mechanical adaptation restores arterial function.

Abstract

This study aimed to model phenomenologically the dynamics of arterial wall remodeling under hypertensive conditions. Sustained hypertension was simulated by a step increase in blood pressure. The arterial wall was considered to be a thick-walled tube made of nonlinear elastic incompressible material. Remodeling rate equations were postulated for the evolution of the geometric dimensions of the hypertensive artery at the zero-stress state, as well as for one of the material constants in the constitutive equations. The driving stimuli for the geometric adaptation are the normalized deviations of wall stresses from their values under normotensive conditions. The geometric dimensions are modulated by the evolution of the deformed inner radius, which serves to restore the level of the flow-induced shear stresses at the arterial endothelium. Mechanical adaptation is driven by the difference between the area compliance under hypertensive and normotensive conditions. The predicted time course of the geometry and mechanical properties of arterial wall are in good qualitative agreement with published experimental findings. The model predicts that the geometric adaptation maintains the stress distribution in arterial wall to its control level, while the mechanical adaptation restores the normal arterial function under induced hypertension.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Rachev et al. (1998) studied this question.

synapsesocial.com/papers/6a1c1fcaea84844e355f7ae5https://doi.org/10.1115/1.2834313
Ask AI
Helpful
Bookmark
Share
View Full Paper